{"product_id":"330101-00-14-90-02-00-bently-nevada-3300-xl-8-mm-proximity-probes","title":"330101-00-14-90-02-00 | Bently Nevada | 3300 XL 8 mm Proximity Probes","description":"\u003ch2\u003eBently Nevada 330101-00-14-90-02-00 3300 XL 8 mm Proximity Probes\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-14-90-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330101\u003c\/strong\u003e proximity probe, serves as the primary 8 mm eddy‑current sensing element used to execute shaft‑position and vibration measurement across 3300 XL platforms. The probe implements a 3\/8‑24 UNF threaded body, 1.4 in case length, and a 9.0 m coaxial lead with ClickLoc termination.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330101\u003c\/strong\u003e: 8 mm proximity probe, 3\/8‑24 UNF thread\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded length = 0.0 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14\u003c\/strong\u003e: Overall case length = 1.4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90\u003c\/strong\u003e: Total cable length = 9.0 m (29.5 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector, standard cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: No agency approvals required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e330101-00-14-90-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e323 g\/m (shipping weight 1.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e1.4 in case length; 3\/8‑24 UNF threaded body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified (standard eddy‑current probe ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive probe; powered by proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbe Type\u003c\/th\u003e\n\u003ctd\u003e3300 XL 8 mm eddy‑current proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThread\u003c\/th\u003e\n\u003ctd\u003e3\/8‑24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnthreaded Length\u003c\/th\u003e\n\u003ctd\u003e0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Length\u003c\/th\u003e\n\u003ctd\u003e9.0 m (29.5 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003e00 = Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation and Eddy‑Current Scaling\u003c\/h3\u003e\n\u003cp\u003e3300 XL probes operate around a nominal −10 VDC gap voltage target, enabling linearized displacement interpretation across the standard 8 mm range. The 330101 probe’s coaxial geometry maintains impedance stability along the 9.0 m cable, reducing drift in proximitor output. Proper seating of the ClickLoc connector ensures consistent rotor‑dynamic signal transfer, minimizing cross‑talk and maintaining phase accuracy in multi‑probe installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 330101 probe be hot‑swapped while the proximitor is energized? A: Physical replacement should only occur with the channel de‑energized to avoid transient gap‑voltage excursions.\u003c\/p\u003e\n\u003cp\u003eQ: Does cable length affect proximitor scaling? A: The 9.0 m length is factory‑matched; altering length or using non‑standard extensions can change impedance and affect calibration.\u003c\/p\u003e\n\u003cp\u003eQ: Are firmware updates required when replacing a probe? A: No firmware resides in the probe. Any adjustments are made at the monitoring module or proximitor configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain clean 3\/8‑24 UNF threads to ensure stable mechanical seating.\u003c\/li\u003e\n\u003cli\u003eRoute coaxial cable away from high‑current conductors to reduce induced noise.\u003c\/li\u003e\n\u003cli\u003eBond shield at the proximitor end only to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends that may alter cable impedance.\u003c\/li\u003e\n\u003cli\u003eVerify ClickLoc connector engagement to ensure stable gap‑voltage reference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45440353894590,"sku":"330101-00-14-90-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/bently-nevada-330101-00-14-10-02-05-3300-xl-8-mm-proximity-probes-ksmn2qlf3fy_e0323188-9467-418c-8880-1991802d197e.png?v=1759029993","url":"https:\/\/www.autooiltech.com\/products\/330101-00-14-90-02-00-bently-nevada-3300-xl-8-mm-proximity-probes","provider":"AutoOilTech Limited","version":"1.0","type":"link"}