{"product_id":"yokogawa-amn11-s1-analog-i-o-nest-module","title":"YOKOGAWA AMN11 S1 Analog I\/O Nest Module","description":"\u003cp\u003eConfigured for 16-channel card rack expansion in Yokogawa DCS chassis systems, the \u003cstrong\u003eYOKOGAWA AMN11 S1\u003c\/strong\u003e (\u003cstrong\u003eAMN11\u003c\/strong\u003e Nest) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAMN11:\u003c\/strong\u003e Base hardware designation for the analog module mounting nest framework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS1:\u003c\/strong\u003e Hardware style revision code specifying physical connector pin alignments and system backplane mounting interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAMN11 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.00 lbs (2.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 cm x 20.3 cm x 25.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e16 module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive backplane rack structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eDedicated analog input and output module backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Conditioning and Channel Isolation Properties\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Isolation Architecture:\u003c\/strong\u003e Provides backplane signal routing paths equipped with individual channel isolation lines to mitigate ground potential differences across analog loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Signal Compatibility:\u003c\/strong\u003e Interconnects analog input and output cards supporting standard 4-20 mA current loops and HART protocol pass-through communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Traces:\u003c\/strong\u003e Integrates heavy-duty internal power distribution planes to deliver stable 24 VDC auxiliary power across all 16 slot connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the AMN11 S1 nest frame?\u003c\/p\u003e\n\u003cp\u003eA: It provides physical mechanical mounting slots and backplane electrical interconnectivity for up to 16 individual analog input and analog output interface modules.\u003c\/p\u003e\n\u003cp\u003eQ: Are active electronics or processing microprocessors embedded directly within the AMN11 S1 assembly?\u003c\/p\u003e\n\u003cp\u003eA: No, the nest functions as an unmanaged passive backplane structural chassis, relying on the inserted I\/O cards and main controller for active logic and signal processing.\u003c\/p\u003e\n\u003cp\u003eQ: Can modules installed in the 16 slots be replaced without shutting down power to the entire nest?\u003c\/p\u003e\n\u003cp\u003eA: Module hot-swapping depends on the specific analog I\/O card installed; however, the passive backplane bus design supports live insertion and removal provided system ESD grounding guidelines are followed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the nest frame securely inside a sealed industrial control enclosure using standard mounting hardware to prevent mechanical vibration wear.\u003c\/li\u003e\n\u003cli\u003eVerify that main 24 VDC power lines are de-energized before connecting the main supply bus to the backplane power terminals.\u003c\/li\u003e\n\u003cli\u003eAlign I\/O module edge connectors carefully with the 16 card guide tracks before pushing firmly to ensure complete seating into the backplane receptacles.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring away from high-voltage AC lines, keeping signal wiring separated by at least 300 mm to preserve analog loop signal integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48491305926846,"sku":"AMN11 S1","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/AMN11-S1_1200x1200_0c66ad71-5156-4e32-b9c3-ff6b4c14832d.jpg?v=1785914026","url":"https:\/\/www.autooiltech.com\/es\/products\/yokogawa-amn11-s1-analog-i-o-nest-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}