{"product_id":"yokogawa-admag-ae-electromagnetic-flowmeter","title":"Yokogawa ADMAG AE Electromagnetic Flowmeter","description":"\u003cp\u003eConfigured for precise conductive fluid flow measurement in industrial process control networks, the \u003cstrong\u003eYokogawa ADMAG AE\u003c\/strong\u003e (\u003cstrong\u003eADMAG AE\u003c\/strong\u003e Electromagnetic Flowmeter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADMAG AE\u003c\/td\u003e\n\u003ctd\u003eStandard Electromagnetic Flowmeter\u003c\/td\u003e\n\u003ctd\u003eIndustrial Process Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADMAG AE-...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eConductive Fluid Automation Networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADMAG AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e200.0 mm x 180.0 mm x 250.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 W max (AC), 10 W max (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 160 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (50\/60 Hz) or 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe ADMAG AE flowmeter integrates 4-20 mA HART loop protocol connectivity to transmit real-time flow rate data directly to supervisory control systems while supporting digital parameter configuration. It features robust channel-to-channel isolation architecture to eliminate ground loops and prevent electromagnetic interference from distorting low-level electrode signals. Furthermore, internal signal conditioning circuitry maintains dielectric strength up to 1500 V AC for 1 minute and ensures insulation resistance of 100 MΩ or greater at 500 V DC across power and signal terminals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the minimum fluid conductivity required for accurate operation of the ADMAG AE flowmeter?\u003c\/p\u003e\n\u003cp\u003eA: The fluid being measured must maintain a minimum electrical conductivity of 5 uS\/cm for the electromagnetic measurement principle to function correctly.\u003c\/p\u003e\n\u003cp\u003eQ: Does the flowmeter support digital communication protocols in addition to standard analog outputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit supports optional HART protocol communication over the 4-20 mA analog loop for remote configuration and diagnostic monitoring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the pipeline is completely de-pressurized and drained before installing the ADMAGE AE flowmeter between mating ANSI, JIS, or DIN process flanges. Mount the sensor horizontally or vertically with upward flow, ensuring the meter pipe remains completely full of fluid during measurement operations. Route the 4-20 mA signal and power cables through dedicated metallic conduits, keeping wiring separated from high-voltage power lines to prevent electrical noise coupling.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48221483204798,"sku":"ADMAGAE","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ADMAGAE_2.png?v=1785291155","url":"https:\/\/www.autooiltech.com\/es\/products\/yokogawa-admag-ae-electromagnetic-flowmeter","provider":"AutoOilTech Limited","version":"1.0","type":"link"}