{"product_id":"yokogawa-adm52c-2-contact-output-module","title":"Yokogawa ADM52C-2 Contact Output Module","description":"\u003cp\u003eConfigured for on\/off control of valves, relays, and actuators in Centum VP and Distributed Control System (DCS) networks, the \u003cstrong\u003eYokogawa ADM52C-2\u003c\/strong\u003e (\u003cstrong\u003eADM52C-2\u003c\/strong\u003e Contact Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADM52C-2\u003c\/td\u003e\n\u003ctd\u003e16-Channel DIN-Rail Mounted Contact Output Module\u003c\/td\u003e\n\u003ctd\u003eYokogawa Centum VP and DCS Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADM52C...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eDistributed Control System Switching Interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADM52C-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150.0 mm x 50.0 mm x 120.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.0 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eContact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe ADM52C-2 module integrates robust electrical isolation architecture between outputs and external devices to eliminate ground loops and prevent electrical noise propagation across CENTUM control nodes. It processes discrete switching commands to drive field actuators while maintaining strict voltage and current thresholds under demanding operational conditions. Furthermore, internal signal conditioning circuitry ensures stable switching performance and protects internal logic components from transient inductive spikes generated by connected inductive loads.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum load current capacity for each output channel on the ADM52C-2 module?\u003c\/p\u003e\n\u003cp\u003eA: Each contact output channel is rated for a maximum load current of 100 mA at 30 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How is the ADM52C-2 module physically mounted within an industrial control cabinet?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for standard DIN-rail mounting, allowing secure installation within system enclosures or field junction racks.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that all power sources connected to the ADM52C-2 module are completely de-energized and locked out prior to physical installation or wiring. Mount the module securely onto a standard DIN-rail, ensuring proper mechanical alignment and stable locking latches. Route external field wiring through dedicated cable ducts, keeping switching control lines separated from high-voltage power cables to minimize electromagnetic interference and maintain electrical isolation integrity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48221446144190,"sku":"ADM52C-2","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ADM12CS2_2_cf81269b-8ceb-4db2-b91d-6a396562f2ef.png?v=1785291183","url":"https:\/\/www.autooiltech.com\/es\/products\/yokogawa-adm52c-2-contact-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}