{"product_id":"ur-7ch-ge-multilin-communication-module","title":"UR-7CH | GE Multilin | Communication Module","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eUR 7CH\u003c\/strong\u003e Communication Module enables Ethernet, serial, and UR‑backplane data exchange for Multilin UR‑series protection relays, supporting secure relay‑to‑relay, relay‑to‑SCADA, and station‑level communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Multilin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: UR‑7CH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Communication Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e: Dual Ethernet channels (redundant or independent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e: RS‑232 \/ RS‑485 interfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e: IEC 61850, DNP3, Modbus, IEC 60870‑5‑103\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Interface\u003c\/strong\u003e: High‑speed UR internal communication bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCybersecurity\u003c\/strong\u003e: Password protection and secure access control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Communication status and channel health monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay Compatibility\u003c\/strong\u003e: All GE UR relays (F35, L60, C30, B30, T60, etc.)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: SCADA integration, relay networking, station communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMulti‑Protocol Support\u003c\/strong\u003e: IEC 61850, DNP3, Modbus, IEC 60870‑5‑103\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDual Ethernet Channels\u003c\/strong\u003e: Redundant or independent communication paths\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSerial Communication\u003c\/strong\u003e: RS‑232\/RS‑485 for legacy system integration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Speed UR Networking\u003c\/strong\u003e: Fast relay‑to‑relay and relay‑to‑controller data exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSecure Access Control\u003c\/strong\u003e: Password‑protected configuration and restricted access\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFull UR Compatibility\u003c\/strong\u003e: Works with all GE Multilin UR protection platforms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHot‑Swappable Design\u003c\/strong\u003e: Replaceable without removing the relay from service\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ – Common Questions\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat_does_UR-7CH_do\u003c\/strong\u003e: It provides Ethernet, serial, and IEC‑compliant communication for UR relays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhich_protocols_are_supported\u003c\/strong\u003e: IEC 61850, DNP3, Modbus, IEC 60870‑5‑103.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs_it_compatible_with_all_UR_relays\u003c\/strong\u003e: Yes, including F35, L60, C30, B30, T60, and others.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes_it_support_redundant_Ethernet\u003c\/strong\u003e: Yes, dual Ethernet channels allow redundancy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs_it_hot_swappable\u003c\/strong\u003e: Yes, it can be replaced without shutting down the relay.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48167614611646,"sku":"UR7CH","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-ur7cm-multilin-digital-input-module-zkymdrguzkf.png?v=1759055384","url":"https:\/\/www.autooiltech.com\/es\/products\/ur-7ch-ge-multilin-communication-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}