{"product_id":"schneider-modicon-quantum-140amm0900-analog-i-o-modules","title":"Schneider Modicon Quantum 140AMM0900 Analog I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric 140AMM0900 is a high-density mixed analog I\/O module designed for the Modicon Quantum PLC platform. This module integrates 4 analog input channels and 2 analog output channels into a single chassis slot, offering a space-efficient solution for complex control loops. It is engineered to facilitate seamless communication between field-level instrumentation and the central processor, supporting a wide array of voltage and current signals for both monitoring and control applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Design:\u003c\/strong\u003e Combines input and output functionality in one module to conserve backplane capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Signal Support:\u003c\/strong\u003e Configurable for standard industrial ranges including 4-20 mA, 0-20 mA, 1-5 VDC, and +\/- 10 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Isolation:\u003c\/strong\u003e Provides 1500 VAC galvanic isolation between field-side signals and the logic backplane to protect against surges and ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Front-facing LED indicators provide immediate visual feedback on channel status, bus communication, and power supply health.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e Onboard low-pass hardware filtering mitigates electromagnetic interference (EMI) in harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis module is suitable for use in demanding industrial sectors such as petrochemical refining, power generation, chemical processing, and water management. It is ideal for applications requiring simultaneous monitoring of process variables (pressure, temperature, flow) and command delivery to actuators like control valves or variable speed drives.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140AMM0900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 (Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2 (Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-20 mA, 1-5 VDC, +\/- 5 VDC, +\/- 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-20 mA, +\/- 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits (unipolar) \/ 13 bits (bipolar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDAC Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e300 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the PLC backplane is powered down before inserting or removing the module to prevent electrical arcing or damage to the backplane connector pins.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analog signal runs to minimize induced noise; ensure shields are grounded at the source or as per site standards.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance in the control panel to allow for adequate airflow and thermal dissipation, keeping the module within the 0 to 60 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eVerify that the external 24 VDC power supply is stable and properly fused before connecting to the field terminals.\u003c\/li\u003e\n\u003cli\u003eHandle with ESD-safe precautions to avoid potential damage to sensitive internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module isolated between channels?\u003c\/strong\u003e\u003cbr\u003eNo, the 140AMM0900 provides 1500 VAC isolation between the field-side and the backplane, but the individual input\/output channels are not isolated from each other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary power requirement?\u003c\/strong\u003e\u003cbr\u003eThe module draws a maximum of 300 mA from the 5 VDC backplane supply and requires an external 24 VDC supply for field operation.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48827113832638,"sku":"140AMM0900","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_6a5824db-eb2d-4e85-a435-ba5b3ddc07cd.jpg?v=1788304954","url":"https:\/\/www.autooiltech.com\/es\/products\/schneider-modicon-quantum-140amm0900-analog-i-o-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}