{"product_id":"schneider-modicon-premium-tsxdey16a2-digital-input-modules","title":"Schneider Electric TSXDEY16A2 Modicon Premium Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric TSXDEY16A2 is a 16-channel discrete input module designed for integration within the Modicon Premium automation architecture. This module is specifically engineered to interface with 24 V AC field signals, providing reliable status monitoring for industrial applications such as process control, power utility management, and heavy-duty machinery. By incorporating robust signal conditioning, the module ensures accurate state detection while mitigating the risks associated with contact bounce and electromagnetic interference common in high-density wiring environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 independent discrete input channels configured in a single isolated group.\u003c\/li\u003e\n\u003cli\u003eIntegrated signal filtering to suppress transient spikes and mechanical contact bounce.\u003c\/li\u003e\n\u003cli\u003eHigh-voltage dielectric isolation (1500 V AC) between field circuits and the internal logic bus.\u003c\/li\u003e\n\u003cli\u003eOptical coupling for enhanced noise immunity and backplane protection.\u003c\/li\u003e\n\u003cli\u003eStandardized HE10 connector interface for efficient field wiring.\u003c\/li\u003e\n\u003cli\u003eReal-time status monitoring and register synchronization via the chassis backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis input module is suitable for a wide range of industrial environments, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eChemical and petrochemical processing plants.\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution systems.\u003c\/li\u003e\n\u003cli\u003eBulk material handling and crushing facilities.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose automation requiring AC signal sensing and interlock management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDEY16A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e16 Discrete AC Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19 to 30 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e1.8 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Latency\u003c\/td\u003e\n\u003ctd\u003e15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the rack is powered down before inserting or removing the TSXDEY16A2 module to prevent electrical damage or backplane faults.\u003c\/li\u003e\n\u003cli\u003eMount the module securely in the designated Modicon Premium chassis slot, ensuring the backplane connector is fully seated.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded cabling for field inputs to minimize EMI pickup, especially in high-noise industrial zones.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring is connected to the HE10 connector block according to the system wiring diagram.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the control cabinet to keep the ambient temperature within the 0 to 60 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to sensitive internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the TSXDEY16A2 module?\u003c\/strong\u003e\u003cbr\u003eThe TSXDEY16A2 is designed to sense the state of 24 V AC field devices and communicate this data to the Modicon Premium PLC, allowing for precise monitoring of switches, interlocks, and auxiliary contacts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the inputs?\u003c\/strong\u003e\u003cbr\u003eThe module is designed to accept 24 V AC signals from your field devices. The internal logic circuitry is powered directly from the 5 VDC rail of the backplane.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48845832290494,"sku":"TSXDEY16A2","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_e12ed2c0-1b65-4947-8e1d-bde1ea52dfe6.jpg?v=1788662140","url":"https:\/\/www.autooiltech.com\/es\/products\/schneider-modicon-premium-tsxdey16a2-digital-input-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}