{"product_id":"schneider-electric-bmxsdi1602-modicon-x80-discrete-input-module","title":"Schneider Electric BMXSDI1602 Modicon X80 Discrete Input Module","description":"\u003cp\u003eConfigured for high-density digital tracking within severe industrial application networks, the \u003cstrong\u003eSchneider Electric BMXSDI1602\u003c\/strong\u003e (\u003cstrong\u003eBMXSDI1602\u003c\/strong\u003e Discrete Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXSDI1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (US)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.115 kg (0.254 lb) net mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32 mm x 134.6 mm x 86 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C (-13 to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical current draw: 100 mA at 24 V DC (backplane) \/ 256 mA DC total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Quantity\u003c\/td\u003e\n\u003ctd\u003e16 non-isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (Sink configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e7500 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e6 ms typical and maximum response timeline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Barrier\u003c\/td\u003e\n\u003ctd\u003e1500 V for 1 minute between channels and bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Hardening\u003c\/td\u003e\n\u003ctd\u003eConformal coating, Gas class 3C4\/Gx, Dust\/Sand class 3S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF Reliability\u003c\/td\u003e\n\u003ctd\u003e265,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon X80 Platform Backplane Architecture\u003c\/h3\u003e\n\u003cp\u003eThe BMXSDI1602 hardware topology decodes parallel physical voltage transitions designed to track system variables across backplane bus communication velocity Licences. By providing a fixed physical link interfacing with up to 16 2-wire or 3-wire sensors conforming to IEC 60947-5-2 limits, the card translates discrete sensor states into system process image blocks without introducing data conversion loop lag.\u003c\/p\u003e\n\u003cp\u003eThe internal physical communication layers manage synchronous packet frames over Profinet \/ EtherNet\/IP deterministic networks via the master chassis connection paths. The instrumentation circuit handles ongoing I\/O density scaling routines by executing dual-threshold sensor validation checks, mapping sensor health to explicit parameters (\u0026lt;14 V DC indicates sensor fault, \u0026gt;18 V DC establishes standard logic state verification). This rugged processing core monitors field execution states under a continuous 3.57 W thermal load while maintaining complete software configuration firmware flash compatibility across standard Schneider Electric EcoStruxure automation platform engineering software tools.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the engineering constraints regarding the non-isolated channel topology of the BMXSDI1602?\u003c\/p\u003e\n\u003cp\u003eA: The 16 input channels share a common internal reference return within the module framework. While there is a 1500 V galvanic isolation barrier between the channel bank and the primary backplane bus, external field wiring must utilize a common power reference to prevent unwanted inter-channel electrical pathways.\u003c\/p\u003e\n\u003cp\u003eQ: How do the integrated diagnostic LEDs respond during an input sensor failure state?\u003c\/p\u003e\n\u003cp\u003eA: The module manages localized status via a red I\/O fault LED and individual green channel indicators. When field voltage drops below the 14 V DC threshold during an active logic cycle, the internal tracking matrix triggers the red fault line and changes the corresponding channel bit state within the CPU diagnostics array.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47604626686142,"sku":"BMXSDI1602","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-05_09-16-34.png?v=1780626047","url":"https:\/\/www.autooiltech.com\/es\/products\/schneider-electric-bmxsdi1602-modicon-x80-discrete-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}