{"product_id":"schneider-bmxddo1602-modicon-x80-discrete-output-module","title":"Schneider BMXDDO1602 Modicon X80 Discrete Output Module","description":"\u003cp\u003eConfigured for high-density discrete switching within industrial automation and process control systems, the \u003cstrong\u003eSchneider Electric BMXDDO1602\u003c\/strong\u003e (\u003cstrong\u003eBMXDDO1602\u003c\/strong\u003e Discrete Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXDDO1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (US)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg (0.26 lb) net mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Modicon X80 single-slot module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Modicon X80 environmental limits (up to 55 deg C \/ 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via local backplane channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Logic\u003c\/td\u003e\n\u003ctd\u003ePositive (Source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Channel\u003c\/td\u003e\n\u003ctd\u003e0.625 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.2 V at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC at 50\/60 Hz for 1 minute (output\/ground and output\/internal logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Hardening\u003c\/td\u003e\n\u003ctd\u003eShort-circuit, overload, overvoltage, and reverse polarity protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF Reliability\u003c\/td\u003e\n\u003ctd\u003e410,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModicon X80 Platform Backplane Architecture\u003c\/h3\u003e\n\u003cp\u003eThe BMXDDO1602 hardware topology decodes parallel binary output command arrays designed to track system variables across backplane bus communication velocity Licences. By utilizing low-latency solid-state switching matrices operating at a 1.2 ms response timeline, the module drives external load coils and interposition relays without introducing data conversion loop lag.\u003c\/p\u003e\n\u003cp\u003eThe internal physical layers manage synchronous bit states over Profinet \/ EtherNet\/IP deterministic networks via the master X80 backplane interface to maintain continuous connection tracking across the central processing unit. The high-density circuitry accommodates scalable I\/O density scaling routines by allowing the paralleling of up to 2 discrete outputs per electrical channel cluster to double current capacity boundaries. This processing core executes continuous preactuator fault diagnostics, cross-referencing real-time threshold voltage vectors (\u0026lt;14 V DC and \u0026gt;18 V DC states) while maintaining full software configuration firmware flash compatibility across standard EcoStruxure Control Expert engineering platforms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What technical limitations govern the paralleling of outputs on the BMXDDO1602 module?\u003c\/p\u003e\n\u003cp\u003eA: A maximum of 2 physical output channels can be wired in parallel to support higher current demands. These channels must belong to the same internal module assembly and be controlled by identical logic tasks within the software application to prevent timing skew and localized overload states.\u003c\/p\u003e\n\u003cp\u003eQ: How does the internal protection logic react during a sustained short-circuit fault on a field channel?\u003c\/p\u003e\n\u003cp\u003eA: The module activates onboard electronic short-circuit and overload protection barriers to immediately clamp and isolate the faulted circuit loop. Concurrently, a preactuator fault flag is set in the process image status byte, which triggers a system diagnostic block warning inside the host controller.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47604624982206,"sku":"BMXDDO1602","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-05_09-15-36_b527afaf-5b76-474f-8a57-fe60a7a3276f.png?v=1780626013","url":"https:\/\/www.autooiltech.com\/es\/products\/schneider-bmxddo1602-modicon-x80-discrete-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}