{"product_id":"honeywell-mc-taih13-51309138-175-analog-input-high-level-fta","title":"Honeywell MC-TAIH13 51309138-175 Analog Input High Level FTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell MC-TAIH13 (51309138-175 Rev D) is a high-level analog input Field Termination Assembly (FTA) engineered for reliable signal integration within Distributed Control System (DCS) architectures. This assembly serves as the critical interface point between field-mounted instrumentation and the control system I\/O modules, facilitating efficient signal distribution while maintaining signal integrity. Designed for demanding process environments, the MC-TAIH13 is widely utilized in sectors such as petrochemical processing, oil refining, and power generation to ensure consistent and accurate data acquisition.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-level analog input interface for streamlined field wiring.\u003c\/li\u003e\n\u003cli\u003eRev D hardware revision featuring enhanced grounding and noise immunity.\u003c\/li\u003e\n\u003cli\u003eRobust terminal design optimized for vibration resistance and long-term contact stability.\u003c\/li\u003e\n\u003cli\u003ePassive interface architecture that simplifies maintenance and reduces potential failure points.\u003c\/li\u003e\n\u003cli\u003eStandardized design for seamless integration into industrial control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis FTA is specifically designed for applications requiring high-density analog signal termination. It is commonly implemented in control rooms and remote instrument enclosures where high-level analog inputs from transmitters, sensors, and other field devices must be reliably routed to the DCS I\/O subsystem. Its architecture helps minimize wiring complexity and downtime associated with connection-related faults.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH13 (51309138-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision\u003c\/td\u003e\n\u003ctd\u003eRev D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input High Level FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Reference)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel or Cabinet Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet power is disconnected before installing or removing the FTA to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the assembly securely on the designated rail or panel, ensuring adequate clearance for cable routing and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring is properly shielded and grounded according to standard industrial practices to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eAdhere to proper ESD handling procedures when interacting with the assembly to protect sensitive signal paths.\u003c\/li\u003e\n\u003cli\u003eCheck all terminal connections for tightness to ensure reliable contact and prevent signal degradation due to vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the MC-TAIH13?\u003c\/strong\u003e\u003cbr\u003eThe MC-TAIH13 is a passive Field Termination Assembly used to connect field instrumentation to Honeywell DCS analog input modules, acting as a bridge to organize and route signals efficiently.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require external power?\u003c\/strong\u003e\u003cbr\u003eThe unit is a passive interface, though it operates within a 24 VDC system environment for signal loop reference purposes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this module compatible with all Honeywell systems?\u003c\/strong\u003e\u003cbr\u003eThe MC-TAIH13 is designed for specific Honeywell DCS environments. Please verify your system I\/O card compatibility with the 51309138-175 order code before installation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48841600204990,"sku":"MC-TAIH13 51309138-175","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_bb16964f-8b39-445e-9a83-002a449b6983.jpg?v=1788567161","url":"https:\/\/www.autooiltech.com\/es\/products\/honeywell-mc-taih13-51309138-175-analog-input-high-level-fta","provider":"AutoOilTech Limited","version":"1.0","type":"link"}