{"product_id":"honeywell-lg1093ac01-flame-detector","title":"Honeywell LG1093AC01 Flame Detector","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell LG1093AC01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eLG1093AC01\u003c\/strong\u003e Flame Detector, operates as a dedicated hardware component for UV radiation detection and flame state monitoring within gas turbine combustion systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLG1093\u003c\/td\u003e\n\u003ctd\u003eFlame sensor series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eStandard configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eCE\/ATEX approval (EEx d IIA T3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e9 ft (2.7 m) cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLG1093AC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1.73 inch O.D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 176 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e180 nm to 260 nm (UV spectrum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The sensor integrates with EG1033 amplifier modules to facilitate signal conditioning, ensuring flame status data is compatible with 4-20 mA control loop input requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e Integration with the amplifier allows flame intensity and fault signals to be relayed to DCS platforms, maintaining high-speed deterministic reporting for turbine safety logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The detector and associated amplifier cabling are designed with high-integrity shielding to prevent electrical noise coupling, maintaining isolation between the flame monitoring circuit and external electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The unit is engineered for operation in high-temperature turbine environments, ensuring signal stability and spectral sensitivity consistency, which is fundamental for accurate UV flame discrimination in presence of black body radiation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this sensor compatible with all GE gas turbine configurations?\u003c\/p\u003e\n\u003cp\u003eA: The LG1093 series is not optimized for GE\/NP DLE (Dry Low-NOx) gas turbines, which require specific pre-selected units. Consult turbine OEM specifications before installation.\u003c\/p\u003e\n\u003cp\u003eQ: Can this sensor be used in hazardous atmospheres?\u003c\/p\u003e\n\u003cp\u003eA: Yes. This model holds CE, ATEX (EEx d IIA T3), and Factory Mutual (Class I, Div 1 and 2) approvals for operation in explosive atmospheres.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the sensor to the combustion chamber viewing port, ensuring the flange is seated correctly against the 428 mbar rated viewing window. Utilize the provided 0.14-inch wide flange for structural alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the armored cable sheath is bonded to the turbine chassis at the amplifier entry point. A low-impedance connection is mandatory for EMC compliance and suppression of induced electrical transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route the 2-conductor armored cable through protective conduits. Maintain strict segregation from high-voltage ignition leads to prevent capacitive noise coupling into the flame signal line.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48160594755774,"sku":"LG1093AC01","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-14_09-33-13_b1a306e2-858b-4a0c-a8ba-0a405f261509.png?v=1784001196","url":"https:\/\/www.autooiltech.com\/es\/products\/honeywell-lg1093ac01-flame-detector","provider":"AutoOilTech Limited","version":"1.0","type":"link"}