{"product_id":"honeywell-fta-t-08-safety-manager-series","title":"Honeywell FTA-T-08 Safety Manager Series","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FTA-T-08\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFTA-T-08\u003c\/strong\u003e Field Termination Assembly Module, operates as a dedicated hardware component for interfacing field actuator devices with safety-related digital output modules within Honeywell Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFTA-T-08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.67 lbs (0.30 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Safety Manager DIN-rail mounting profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive board assembly (relay coils energized via control module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4 isolated output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e115\/230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Connector\u003c\/td\u003e\n\u003ctd\u003e1 x 4F FTA connector per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eT10 terminal strip connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Safety Loop Integration\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-08 coordinates digital signaling between internal processor cards and critical high-voltage field devices under SIL-rated logic parameters.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL3 Certification \u0026amp; TMR Integrity:\u003c\/strong\u003e Designed to interface directly with Honeywell's Triple Modular Redundant (TMR) safety systems. The module pathways ensure that diagnostic signals from the active output cards continuously monitor the electrical health of the field loops without causing spurious trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation Protection:\u003c\/strong\u003e Each of the 4 channels features independent terminal physical spacing and relay isolation barriers. This prevents high-voltage 115\/230 VAC line transients on the field side from propagating backward into the low-voltage DC logic backplanes of the Safety Manager cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe State Execution:\u003c\/strong\u003e The board is physically configured to enforce a de-energize-to-trip (DTT) action. In the event of a total controller power loss or communication failure, the relay pathways drop out, bringing connected valves or contactors to their predefined, physically secure fail-safe states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e Can this terminal assembly be used for standard analog control loops?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e No. The FTA-T-08 is dedicated strictly to digital output (DO) switching. It is specifically designed to handle high-voltage AC digital outputs (115\/230 VAC) and cannot process analog 4-20 mA or low-voltage DC signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e What is the function of the 4F FTA connectors?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e The 4F connectors provide standard, pre-fabricated cable interfaces to connect the module directly to the matching controller I\/O card rack. This interface minimizes individual wiring faults and speeds up cabinet fabrication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e How are the individual outputs protected against overcurrent events?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e The board features socketed, field-replaceable fuses for each of the 4 channels. If a short circuit occurs in the field wiring, the local fuse opens to protect the printed circuit traces of the termination assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting and Thermal Spacing:\u003c\/strong\u003e Mount the module horizontally on a standard TS35 DIN-rail. Ensure a minimum clearance of 50 mm (2 inches) above and below the terminal block assemblies to allow for ambient convective cooling of adjacent hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Shielding and Routing Separation:\u003c\/strong\u003e Strip field wires to the recommended T10 terminal dimensions. Route the high-voltage 115\/230 VAC field lines through separate wire ducts away from low-voltage DC communication bus cables to avoid electromagnetic cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Earth (PE) Grounding:\u003c\/strong\u003e Connect the dedicated ground terminal on the FTA chassis to the master instrument safety ground bar using a low-impedance copper conductor. This is critical to ensure local shielding networks divert line transients safely to ground.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48167323369662,"sku":"FTA-T-08","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-16_10-08-25_241407ea-07b3-4412-bc75-d335693e539f.png?v=1784174782","url":"https:\/\/www.autooiltech.com\/es\/products\/honeywell-fta-t-08-safety-manager-series","provider":"AutoOilTech Limited","version":"1.0","type":"link"}