{"product_id":"honeywell-fc-bsdi-16uni-adapter-module","title":"Honeywell FC-BSDI-16UNI Adapter Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell FC-BSDI-16UNI\u003c\/strong\u003e, also cataloged as the Adapter Module, is designed for integration within Safety Manager and Experion PKS systems. It provides a universal interface for digital input signals, ensuring reliable connectivity and isolation in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct No.:\u003c\/strong\u003e FC-BSDI-16UNI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Adapter Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity:\u003c\/strong\u003e 16 digital input channels (universal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Dry contact \/ voltage input (configurable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel‑to‑channel and logic isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Compliance:\u003c\/strong\u003e Compatible with Safety Manager I\/O bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Terminal block adapter interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 24 VDC nominal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +60 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e ~1.5 Kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUniversal Input Handling:\u003c\/strong\u003e Supports multiple digital input types for flexible field integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Channel Density:\u003c\/strong\u003e 16 input channels per module for efficient system design.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRobust Isolation:\u003c\/strong\u003e Channel‑to‑channel isolation ensures safe and reliable operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Seamlessly integrates with Honeywell Safety Manager and Experion PKS systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Lightweight adapter module for easy installation and maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: How many input channels does the FC-BSDI-16UNI support? A: It supports 16 universal digital input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What type of signals can be connected? A: Dry contact and voltage input signals are supported.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Is the module isolated? A: Yes, it provides channel‑to‑channel and logic isolation for enhanced reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMount the FC-BSDI-16UNI securely in the designated rack slot.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnect field wiring to the terminal block adapter interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure proper grounding and shielding to minimize interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify input signal configuration during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePerform diagnostic checks to confirm stable input recognition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47624874885310,"sku":"FC-BSDI-16UNI","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/FC-BN-1608_3.png?v=1779864629","url":"https:\/\/www.autooiltech.com\/es\/products\/honeywell-fc-bsdi-16uni-adapter-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}