{"product_id":"honeywell-900p01-0501-power-supply-module","title":"Honeywell 900P01-0501 Power Supply Module","description":"\u003ch2\u003eHoneywell 900P01‑0501 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900P01‑0501\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900P01‑0501\u003c\/strong\u003e power supply module, operates as a dedicated AC‑to‑DC conversion unit for stable backplane energizing within HC900 control assemblies. It conditions wide‑range AC input, manages inrush behavior, and maintains regulated DC output for controller and I\/O module loading.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e900P01‑0501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eHC900 Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e820 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e137 mm H × 72.6 mm W (5.4 in × 2.86 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e0 deg C to 60 deg C (T4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eInput rating 130 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e90 to 264 V AC, 47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003ctd\u003e1.4 A max continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInrush Current\u003c\/th\u003e\n\u003ctd\u003e40 A peak‑to‑peak for 120 ms at 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Rating\u003c\/th\u003e\n\u003ctd\u003e58 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHold‑Up Time\u003c\/th\u003e\n\u003ctd\u003e20 ms @ 115 V AC, 60 Hz (maximum load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse\u003c\/th\u003e\n\u003ctd\u003eInternal non‑replaceable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWiring\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, 0.3 mm² to 3.3 mm² (#12–22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Jacks\u003c\/th\u003e\n\u003ctd\u003e5 V DC, 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4‑20 mA HART Loop Protocol and Isolation Behavior\u003c\/h3\u003e\n\u003cp\u003eAligned with Honeywell process‑instrumentation conventions, the 900P01‑0501 maintains stable DC output conditions required for downstream \u003cstrong\u003e4‑20 mA HART loop protocol\u003c\/strong\u003e devices. The regulated supply minimizes ripple that could interfere with HART frequency modulation. When powering mixed analog modules, \u003cstrong\u003echannel‑to‑channel isolation\u003c\/strong\u003e within HC900 I\/O is preserved, preventing cross‑loop interference and maintaining predictable analog update timing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 900P01‑0501 be hot‑swapped during operation?\u003c\/strong\u003e A: The module is not designed for hot‑swap. Power must be removed from the HC900 chassis before insertion or removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the inrush current affect upstream protection devices?\u003c\/strong\u003e A: The 40 A peak inrush may require coordination with upstream breakers or fuses to avoid nuisance tripping during startup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the 5 V DC and 24 V DC test jacks intended for powering external loads?\u003c\/strong\u003e A: No. The test jacks are measurement points only and should not be used as auxiliary power outputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain proper torque on screw‑type terminals to ensure stable conductor engagement within the specified 0.3 mm² to 3.3 mm² range.\u003c\/li\u003e\n\u003cli\u003eRoute AC input wiring separately from low‑voltage DC output conductors to reduce electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eBond shielded cable grounds at a single point to avoid circulating currents.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate airflow around the module to prevent thermal buildup within the enclosure.\u003c\/li\u003e\n\u003cli\u003eUse test jacks strictly for diagnostic measurement; avoid loading them with external circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48206388166846,"sku":"Power Supply Module","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/900P01-0001_3.jpg?v=1782289221","url":"https:\/\/www.autooiltech.com\/es\/products\/honeywell-900p01-0501-power-supply-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}