{"product_id":"honeywell-2mlr-cpuh-t-high-speed-cpu-module","title":"Honeywell 2MLR‑CPUH\/T High‑Speed CPU Module","description":"\u003ch2\u003eHoneywell 2MLR‑CPUH\/T High‑Speed CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 2MLR‑CPUH\/T\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2MLR‑CPUH\/T\u003c\/strong\u003e high‑speed CPU module, serves as the primary processor used to execute cyclic scans, interrupt‑driven tasks, and synchronous I\/O control across MasterLogic‑200 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e2MLR‑CPUH\/T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eMasterLogic‑200 Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.257 kg (shipping weight 2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003e1173 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eHigh‑Speed CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram Execution\u003c\/th\u003e\n\u003ctd\u003eCyclic scan, time‑driven interrupts, internal memory interrupts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Control Method\u003c\/th\u003e\n\u003ctd\u003eScan‑synchronous batch processing (refresh), direct I\/O via program instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupported Languages\u003c\/th\u003e\n\u003ctd\u003eLadder Diagram, Sequential Function Chart, Structured Text, Instruction List (view only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperators\u003c\/th\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram Memory\u003c\/th\u003e\n\u003ctd\u003e7 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlash Memory\u003c\/th\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax I\/O Bases\u003c\/th\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Slots\u003c\/th\u003e\n\u003ctd\u003e372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Network \/ Remote I\/O\u003c\/th\u003e\n\u003ctd\u003e128,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ Deterministic Network Behavior\u003c\/h3\u003e\n\u003cp\u003eAs a MasterLogic‑200 CPU, the module aligns with Honeywell’s deterministic industrial‑network conventions. When deployed in systems using \u003cstrong\u003eProfinet\u003c\/strong\u003e or similar deterministic Ethernet architectures, the CPU maintains stable scan‑cycle timing and predictable I\/O refresh behavior. Internal firmware scheduling ensures consistent execution of interrupt‑driven tasks, while backplane communication supports \u003cstrong\u003eI\/O density scaling\u003c\/strong\u003e across large multi‑rack configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 2MLR‑CPUH\/T be replaced while the rack is energized?\u003c\/strong\u003e A: No. The CPU is not hot‑swappable. The MasterLogic‑200 rack must be de‑energized before removal or insertion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does interrupt‑driven execution affect cyclic scan timing?\u003c\/strong\u003e A: Time‑driven and memory‑driven interrupts execute with priority. Cyclic scan timing adjusts automatically based on interrupt load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the CPU manage large I\/O counts?\u003c\/strong\u003e A: The CPU supports up to 128,000 network\/remote I\/O points using synchronous refresh and direct‑I\/O instructions for time‑critical operations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the CPU vertically until the backplane connector fully engages; avoid lateral force that may stress the connector.\u003c\/li\u003e\n\u003cli\u003eRoute communication wiring separately from high‑voltage conductors to reduce electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eBond shielded cable grounds at a single termination point to prevent circulating currents.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate airflow around the CPU to avoid thermal buildup within the enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify correct I\/O addressing and scan‑cycle configuration before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48207213461694,"sku":"2MLR‑CPUH\/T","price":470.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/2MLR-CPUH_3.png?v=1785137217","url":"https:\/\/www.autooiltech.com\/es\/products\/honeywell-2mlr-cpuh-t-high-speed-cpu-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}