{"product_id":"honeywell-10014-i-f-fail-safe-digital-output-module","title":"Honeywell 10014\/I\/F Fail Safe Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell 10014\/I\/F is a high-reliability, fail-safe digital output module engineered for safety-critical control environments. This module provides 8 isolated 24 VDC solid-state output channels, specifically designed to transition to a de-energized state upon the detection of a system fault. It is a core component for Safety Instrumented Systems (SIS), providing the deterministic performance required for emergency shutdown and process protection in demanding industrial sectors such as oil and gas, chemical manufacturing, and power utility plants.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvides 8 independent, galvanically isolated sourcing output channels.\u003c\/li\u003e\n\u003cli\u003eSolid-state switching architecture ensures high-speed response and eliminates mechanical wear.\u003c\/li\u003e\n\u003cli\u003eDesigned for fail-safe operation; outputs automatically de-energize during power loss or internal diagnostic failures.\u003c\/li\u003e\n\u003cli\u003eDirect compatibility with common field devices, including solenoid valves, relays, and industrial shutdown actuators.\u003c\/li\u003e\n\u003cli\u003eRack-mountable design for efficient integration into standard Honeywell safety controller backplanes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily utilized in safety-critical loops where reliable, high-integrity output signaling is essential. Typical applications include emergency shutdown systems (ESD), process trip circuits, and alarm annunciation systems in environments where safety and uptime are non-negotiable.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10014\/I\/F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 Isolated Digital Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSolid State Sourcing, 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e550 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Lamp Load\u003c\/td\u003e\n\u003ctd\u003e120 mA (approx. 2.9 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e1 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.0 V at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W to 5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is fully powered down before inserting or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eUse appropriate ESD protection when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring is properly shielded and routed away from high-voltage or high-EMI power lines to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eConfirm proper grounding of the rack backplane to ensure effective noise immunity and module performance.\u003c\/li\u003e\n\u003cli\u003eCheck all terminal connections for secure seating to prevent intermittent contact in high-vibration environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the 10014\/I\/F module?\u003c\/strong\u003e\u003cbr\u003eThe 10014\/I\/F is a fail-safe digital output module designed to safely de-energize connected field devices when a fault is detected, supporting critical safety shutdown protocols.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the output channels?\u003c\/strong\u003e\u003cbr\u003eYes, the module operates within a 24 VDC system; ensure the field power supply is correctly matched to the module's rated voltage and current requirements.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48852217987262,"sku":"10014\/I\/F","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_96c175e5-bd64-4e33-a3c4-2bdc5dd5f898.jpg?v=1788773561","url":"https:\/\/www.autooiltech.com\/es\/products\/honeywell-10014-i-f-fail-safe-digital-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}