{"product_id":"general-electric-is200vgenh1b-mark-vi-generator-monitor-and-trip-board","title":"GE Fanuc IS200VGENH1B Mark VI Generator Monitor and Trip Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IS200VGENH1B is a specialized Generator Monitor and Trip Board engineered by GE Fanuc for the Mark VI Speedtronic control platform. This module is essential for the protection and monitoring of industrial power generation assets, providing critical real-time analysis of three-phase voltage and current vectors. By sampling high-speed electrical inputs, the board enables the calculation of active power, reactive power, and power factor metrics, allowing for the immediate detection of phase imbalances or under-voltage conditions to trigger protective trip loops.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for integration with the Mark VI Speedtronic control system.\u003c\/li\u003e\n\u003cli\u003eUtilizes eight independent signal processing channels for high-precision data acquisition.\u003c\/li\u003e\n\u003cli\u003eFeatures hardware-level trip logic to ensure rapid response times without software latency.\u003c\/li\u003e\n\u003cli\u003eConstructed with robust surface mount technology (SMT) for high-reliability operation in demanding industrial environments.\u003c\/li\u003e\n\u003cli\u003eDesigned to work in conjunction with TGEN terminal boards for seamless system connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in heavy industrial power systems, including large-scale electrical utility grids, thermal power generation facilities, and oil and gas refinery power distribution centers. Its core function is to safeguard alternators from electrical faults and prevent cascading grid failures.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VGENH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input Range\u003c\/td\u003e\n\u003ctd\u003e0.3532 to 4.054 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 Watts (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the Mark VI control rack is powered down before attempting to insert or remove the module.\u003c\/li\u003e\n\u003cli\u003eHandle the board using proper ESD (Electrostatic Discharge) mitigation protocols to prevent component damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is correctly seated in the VME backplane to ensure proper communication and power delivery.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all field inputs to minimize EMI interference, which is critical for accurate voltage and current vector sampling.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the control cabinet to stay within the specified operating temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary role of the IS200VGENH1B?\u003c\/h3\u003e\u003cp\u003eThe IS200VGENH1B functions as a generator monitoring and protection board that computes power parameters and executes hardware-level trips to protect generation equipment from electrical damage.\u003c\/p\u003e\u003ch3\u003eIs this board compatible with other terminal boards?\u003c\/h3\u003e\u003cp\u003eYes, this module is specifically designed to operate alongside TGEN terminal boards to facilitate connection to field instrumentation.\u003c\/p\u003e\u003ch3\u003eDoes this board require software configuration for trip logic?\u003c\/h3\u003e\u003cp\u003eThe module is designed for hardware-level trip execution, allowing for fast response times independent of software processing cycles.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":48852293550270,"sku":"IS200VGENH1B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_5e8b7880-f3c8-4bfc-ad6a-c476ee8168f8.jpg?v=1788776656","url":"https:\/\/www.autooiltech.com\/es\/products\/general-electric-is200vgenh1b-mark-vi-generator-monitor-and-trip-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}