{"product_id":"general-electric-is200tturh1cfdis230tntrh1c-terminal-turbine-board","title":"General Electric IS200TTURH1CFD(IS230TNTRH1C) Terminal Turbine Board","description":"\u003cp\u003eConfigured for turbine protection, speed sensing, and breaker control in Mark VIe turbine control system platforms, the \u003cstrong\u003eGeneral Electric IS200TTURH1CFD(IS230TNTRH1C)\u003c\/strong\u003e (\u003cstrong\u003eIS200TTURH1CFD(IS230TNTRH1C)\u003c\/strong\u003e Terminal Turbine Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200TTURH1CFD(IS230TNTRH1C)\u003c\/strong\u003e: Turbine-Specific Primary Trip Board designated as a reliable upgrade of the IS200TTURH1 supporting simplex and Triple Modular Redundant (TMR) configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TTURH1CFD(IS230TNTRH1C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e305 mm x 229 mm x 76 mm (Alternate: 8.26 cm H x 4.19 cm W x 12.1 cm D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power rail distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output Channels\u003c\/td\u003e\n\u003ctd\u003e48 total via 2 pluggable terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Sensor Range\u003c\/td\u003e\n\u003ctd\u003e2 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Sensor Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity and Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe IS200TTURH1CFD(IS230TNTRH1C) integrates advanced interface systems and signal conditioning to preserve operational velocity and data integrity across turbine protection networks. Key design parameters include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect wiring interface to the VTUR module via JR1 and JR5 communication pathways, ensuring deterministic data exchange and minimal backplane bus communication velocity latency.\u003c\/li\u003e\n\u003cli\u003eComprehensive I\/O density scaling supporting 48 total channels via pluggable terminal blocks for TTL speed pickups, generator voltage, and shaft voltage\/current signals.\u003c\/li\u003e\n\u003cli\u003eFirmware flash compatibility and hardware support for both simplex and Triple Modular Redundant (TMR) configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200TTURH1CFD(IS230TNTRH1C) module support live hot-swapping under power? A: No. Power must be isolated from the specific rack slot prior to module extraction or insertion to prevent backplane pin damage and transient current surges.\u003c\/p\u003e\n\u003cp\u003eQ: What are the speed sensor input parameters and accuracy for this board? A: The board supports a speed sensor range from 2 Hz to 20 kHz with an accuracy of +\/-0.05% and an input sensitivity of 27 mV peak for MPU inputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the panel securely using the factory-drilled mounting holes, maintaining the specified dimensions of 305 mm x 229 mm x 76 mm.\u003c\/li\u003e\n\u003cli\u003eTerminate field instrumentation wiring onto the 2 pluggable terminal blocks, verifying correct relay configuration for K25, K25P, and K25A 125 VDC breaker systems.\u003c\/li\u003e\n\u003cli\u003eVerify that environmental conditions remain strictly within the -30 deg C to +65 deg C operating temperature window before energizing the control system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48205904773310,"sku":"IS200TTURH1CFD（IS230TNTRH1C）","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IS200TTURH1CFD_IS230TNTRH1C_b4d4627e-190b-486e-8a6d-016cb012aa70.png?v=1785116038","url":"https:\/\/www.autooiltech.com\/es\/products\/general-electric-is200tturh1cfdis230tntrh1c-terminal-turbine-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}