{"product_id":"ge-mark-vi-is200tproh1bbb-protective-termination-board","title":"GE Mark VI  IS200TPROH1BBB Protective Termination Board","description":"\u003ch2\u003eGE IS200TPROH1BBB Protective Termination Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200TPROH1BBB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TPROH1BBB\u003c\/strong\u003e protective termination board, serves as the primary TPRO module used to execute conditioned termination of protection‑related turbine signals across Mark VI Speedtronic platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS200TPROH1BBB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMark VI Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eProtective Termination Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eTwo 48‑point barrier blocks (total 96 terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRelays \/ Contactors\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eTwo red square relay devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMOVs\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMultiple red metal‑oxide varistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePotentiometers\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eThree variable resistors (R‑designated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCapacitors\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eYellow capacitors, paired and individual placements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDiodes\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMultiple black rectangular diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eThree board‑edge connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eAs part of GE’s Mark VI control architecture, the IS200TPROH1BBB aligns with deterministic backplane timing for turbine protection signals. The board’s termination layout supports stable propagation delay when interfacing with protection processors, ensuring predictable routing of trip‑related inputs. Firmware flash compatibility resides entirely in upstream I\/O packs; the TPRO board contains no programmable logic. I\/O density scaling is achieved through fixed hardware design, including MOV arrays for surge suppression, resistor banks for signal conditioning, and diode networks for protection‑path isolation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IS200TPROH1BBB support hot‑swap replacement?\u003c\/strong\u003e A: No. The board must be replaced only with cabinet power isolated to avoid unintended trip‑signal transitions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there any configurable jumpers on the board?\u003c\/strong\u003e A: No. The board is fully fixed‑configuration and relies on upstream processor settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many wiring points are available?\u003c\/strong\u003e A: Two terminal blocks provide a total of 96 terminals supporting 48 signal pairs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain strict wiring discipline on all protection‑related terminations.\u003c\/li\u003e\n\u003cli\u003eEnsure barrier‑type terminal blocks are fully seated before energizing the system.\u003c\/li\u003e\n\u003cli\u003eKeep wiring isolated from high‑energy conductors to reduce surge coupling.\u003c\/li\u003e\n\u003cli\u003eVerify proper seating of all board‑edge connectors to maintain stable communication with protection processors.\u003c\/li\u003e\n\u003cli\u003eFollow GE installation manuals for grounding, torque values, and cabinet layout requirements.\u003c\/li\u003e\n\u003cli\u003eInspect MOV arrays and diode networks during maintenance for signs of overstress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48158000414910,"sku":"IS200TPROH1BBB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200tsvoh1bdc-servo-terminal-board-cthvlpy1vmw.png?v=1759132157","url":"https:\/\/www.autooiltech.com\/es\/products\/ge-mark-vi-is200tproh1bbb-protective-termination-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}