{"product_id":"ge-is220staih2acb-analog-input-module","title":"GE IS220STAIH2ACB Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS220STAIH2ACB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS220STAIH2ACB\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel analog signal acquisition and 16-bit analog-to-digital conversion within Mark VIe control architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220STAIH2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe compact rack format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e28 VDC nominal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 differential analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-5 V, +\/-10 V, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module communicates via high-speed Ethernet-based backplane protocols designed for deterministic data exchange within Mark VIe control racks. Firmware flash compatibility is maintained through onboard memory blocks that synchronize operational logic with system controller revisions. Backplane bus communication velocity executes real-time data acquisition across all eight differential channels without propagation delay. I\/O density scaling allows dense multi-channel analog collection while preserving channel-to-channel isolation and protection against overvoltage and surge events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the input signal range capabilities of the IS220STAIH2ACB module?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts differential analog inputs spanning +\/-5 V, +\/-10 V, 0-20 mA, and 4-20 mA configurations, processed via a 16-bit analog-to-digital converter.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific hot-swap constraints when replacing this module in an active rack?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping must follow strict Mark VIe safety procedures, ensuring local control power is isolated or proper slot permit protocols are executed to prevent backplane communication faults.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply voltage is required for continuous operation?\u003c\/p\u003e\n\u003cp\u003eA: The hardware requires a nominal 28 VDC input supplied via the rack backplane infrastructure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the Mark VIe control rack power is de-energized prior to inserting or extracting the module.\u003c\/li\u003e\n\u003cli\u003eInspect the target backplane slot for debris or bent pins before physical insertion.\u003c\/li\u003e\n\u003cli\u003eSlide the module along the internal chassis guides until the rear connectors mate securely with the backplane bus.\u003c\/li\u003e\n\u003cli\u003eFasten the top and bottom retention screws to guarantee mechanical stability and proper ground continuity against vibration.\u003c\/li\u003e\n\u003cli\u003eVerify status indicators and network communication handshake via the system engineering workstation upon powering up the rack.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48406563651774,"sku":"IS220STAIH2ACB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-07_17-37-28_dac7a33d-18c7-49f2-ab03-f8b0a50af63f.png?v=1785812020","url":"https:\/\/www.autooiltech.com\/es\/products\/ge-is220staih2acb-analog-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}