{"product_id":"ge-is200acleh1bcbis215acleh1b-application-control-layer-module","title":"GE IS200ACLEH1BCB(IS215ACLEH1B) Application Control Layer Module","description":"\u003cp\u003eConfigured for application-level logic execution and real-time processing in Mark VI Turbine Control System platforms, the \u003cstrong\u003eGeneral Electric IS200ACLEH1BCB\u003c\/strong\u003e (\u003cstrong\u003eIS200ACLEH1BCB\u003c\/strong\u003e \/ \u003cstrong\u003eIS215ACLEH1B\u003c\/strong\u003e Application Control Layer Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model \u003cstrong\u003eIS200ACLEH1BCB\u003c\/strong\u003e (alternatively designated as \u003cstrong\u003eIS215ACLEH1B\u003c\/strong\u003e) belongs to the General Electric Mark VI Turbine Control System architecture. Based on standard part number configuration rules, the base designation identifies the Application Control Layer Module form factor, while the specific suffix string encodes the processor revision level, memory configuration, and hardware assembly matrix.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ACLEH1BCB \/ IS215ACLEH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndustrial Standard Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.75 cm x 9.50 cm x 3.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial Standard Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Rack Backplane Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eApplication Control Layer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates high-speed microprocessors alongside 128 MB main memory, 8 MB DRAM, and 4 MB BIOS to execute precise turbine control algorithms. Configurable firmware flash compatibility and backplane bus communication velocity ensure deterministic data transfer across the system infrastructure. Integrated Ethernet and ISBus interfaces facilitate seamless communication with other system components, while built-in redundancy support enhances overall system uptime.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the application control layer module support hot-swap replacement under live system power?\u003c\/p\u003e\n\u003cp\u003eA: No, rack power and backplane supplies must be completely de-energized prior to handling or replacing the \u003cstrong\u003eGeneral Electric IS200ACLEH1BCB\u003c\/strong\u003e module to prevent electrical faults and bus communication errors.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module interface with external networks and internal system racks?\u003c\/p\u003e\n\u003cp\u003eA: It utilizes dedicated Ethernet and ISBus interfaces for external and peer-to-peer communication, and mounts directly into the EX2100 exciter board rack.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module securely within the designated EX2100 exciter board rack enclosure, adhering to the 14.75 cm x 9.50 cm x 3.50 cm physical dimensions to ensure proper backplane engagement. Route Ethernet and ISBus communication cables away from high-voltage excitation conduits to minimize electromagnetic interference. Verify that all rack connections and grounding paths are fully secured prior to system energization.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48235058659518,"sku":"IS200ACLEH1BCB(IS215ACLEH1B)","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IS200ACLEH1BCB-IS215ACLEH1B_435782eb-fb26-45c3-afc2-9662bbc49448.jpg?v=1785467761","url":"https:\/\/www.autooiltech.com\/es\/products\/ge-is200acleh1bcbis215acleh1b-application-control-layer-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}