{"product_id":"ge-fanuc-ic693cpu364-cj-cpu-processor","title":"GE Fanuc IC693CPU364-CJ CPU Processor","description":"\u003cp\u003eConfigured for central processing and baseplate management in Series 90-30 PLC architectures, the \u003cstrong\u003eGE Fanuc IC693CPU364-CJ\u003c\/strong\u003e (\u003cstrong\u003eIC693CPU364-CJ\u003c\/strong\u003e CPU Processor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Description \/ Hardware State\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693\u003c\/td\u003e\n\u003ctd\u003eBase platform designation indicating Series 90-30 PLC hardware infrastructure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU364\u003c\/td\u003e\n\u003ctd\u003eCore processor functional identifier denoting 80386EX architecture with integrated Ethernet communications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-CJ\u003c\/td\u003e\n\u003ctd\u003eHardware revision and regional manufacturing suffix indicating specific firmware iteration and component build state.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CPU364-CJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30 single-slot module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.51 A at +5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003e80386EX, 25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003e0.22 ms per 1K logic \/ Boolean contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Support\u003c\/td\u003e\n\u003ctd\u003e1 CPU baseplate, up to 7 expansion\/remote baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module communicates via high-speed backplane bus communication velocity across the Series 90-30 rack system to coordinate I\/O data exchange. Firmware flash compatibility is supported through onboard memory blocks, allowing synchronization with programming software revisions and Ethernet communication stacks. Backplane bus communication velocity operates within deterministic limits to manage up to seven expansion or remote baseplates without data collision. I\/O density scaling enables expansive remote node integration while maintaining fast scan rates and reliable register updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical load requirements of the IC693CPU364-CJ module on the baseplate power supply?\u003c\/p\u003e\n\u003cp\u003eA: The CPU draws 1.51 A at +5 VDC from the backplane power supply bus.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit support hot-swapping within an active Series 90-30 rack?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is restricted; main rack power must be completely de-energized before inserting or extracting the CPU module to prevent backplane bus damage or data corruption.\u003c\/p\u003e\n\u003cp\u003eQ: What are the specifications of the onboard Ethernet protection fuse?\u003c\/p\u003e\n\u003cp\u003eA: The Ethernet circuit utilizes a replaceable fuse rated at 125 V, 1 A with physical dimensions of 2.69 x 2.69 x 6.1 mm.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the PLC baseplate power supply is fully de-energized and locked out prior to handling or installing the module.\u003c\/li\u003e\n\u003cli\u003eInspect the CPU slot for mechanical debris and align the module edge connectors with the backplane guides.\u003c\/li\u003e\n\u003cli\u003ePush the module firmly into the slot until the backplane connector is fully seated and secure the top\/bottom retaining latches.\u003c\/li\u003e\n\u003cli\u003eConnect the Ethernet communication cable to the onboard RJ45 port, ensuring network wiring adheres to standard industrial shielding practices.\u003c\/li\u003e\n\u003cli\u003eApply system power and observe the LED status indicators to verify successful power-up diagnostics and CPU operational mode.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48406782640318,"sku":"IC693CPU364-CJ","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-29_09-22-12_48b74452-db52-444f-81e9-755032e96a1b.png?v=1785812084","url":"https:\/\/www.autooiltech.com\/es\/products\/ge-fanuc-ic693cpu364-cj-cpu-processor","provider":"AutoOilTech Limited","version":"1.0","type":"link"}