{"product_id":"ge-ds200tceag1bre-mark-v-emergency-overspeed-board","title":"GE DS200TCEAG1BRE Mark V Emergency Overspeed Board","description":"\u003cp\u003eConfigured for overspeed monitoring and flame detection trip operations in Speedtronic Mark V Gas Turbine Control Systems, the \u003cstrong\u003eGE DS200TCEAG1BRE\u003c\/strong\u003e (\u003cstrong\u003eDS200TCEA\u003c\/strong\u003e Emergency Overspeed Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe precise modular assembly and revision path for the \u003cstrong\u003eDS200TCEAG1BRE\u003c\/strong\u003e are detailed below:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSegment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Prefix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eStandard domestic modular board assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCEA\u003c\/td\u003e\n\u003ctd\u003eEmergency Overspeed Board designator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrouping Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG1\u003c\/td\u003e\n\u003ctd\u003eGroup 1 hardware layout configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRevision 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eFirst functional hardware modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRevision 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003eSecond functional hardware modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArtwork Rev\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003ePrinted circuit board artwork design pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCEAG1BRE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.30 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V card slot layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via Mark V control backplane rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd\u003eOnboard high-performance microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Configuration\u003c\/td\u003e\n\u003ctd\u003eSocketed Programmable Read-Only Memory (PROM) modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Jumpers\u003c\/td\u003e\n\u003ctd\u003e30 hardware-configurable jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Protection\u003c\/td\u003e\n\u003ctd\u003e3 physical high-capacity fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003e2 x female bayonet connections, multi-pin ribbon ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePower Supply \u0026amp; Interface Bus Technology\u003c\/h3\u003e\n\u003cp\u003eThe TCEA architecture integrates dedicated processing resources with local signal pathways to ensure hardware-level turbine safety execution.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility \u0026amp; Processing:\u003c\/strong\u003e The onboard microprocessor executes safety monitoring routines independent of the main controller core. The system firmware is housed in socketed, field-replaceable PROM modules to prevent unauthorized logical overwrites or remote firmware corruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Signal Processing:\u003c\/strong\u003e Evaluates magnetic speed pickup signals and compares pulse frequencies to hardcoded overspeed thresholds. If limits are violated, hardware relays on the trip bus are de-energized to shut down the turbine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Safety Interfacing:\u003c\/strong\u003e Monitors optical flame detectors in real-time, instantly transmitting flame status inputs to the core processing unit and triggering isolated trip sequences in the event of flame loss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e What function do the physical bayonet connectors on the DS200TCEAG1BRE serve?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e The bayonet connectors provide low-resistance, vibration-resistant connections for critical high-speed sensor cables, directly linking the speed pickups and flame detection lines to the processing circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e How do the 30 onboard jumpers alter the operation of the board?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e The jumpers allow hardware-level configuration of speed sensor frequency scaling, trip limits, flame detector signal thresholds, and test-loop routing parameters before the board is put into active operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e What is the procedure for swapping the socketed PROM modules during a board replacement?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Prior to board installation, use an extraction tool to carefully remove the PROMs from the faulty board and transfer them into the exact matching sockets on the replacement board to preserve local configuration parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBayonet Cable Disconnection Safety:\u003c\/strong\u003e When disconnecting the male bayonet plugs from the board's female terminals, hold the connector body firmly with one hand while steadying the PCB surface with the other. This prevents excessive bending stresses, trace cracking, or mechanical board sliding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Protection:\u003c\/strong\u003e Always wear a grounded ESD wrist strap and work on a dissipative surface when handling this card to protect the microprocessor and CMOS components from static damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDe-energization Requirement:\u003c\/strong\u003e Completely power down the Mark V cabinet prior to installing or removing the card. Failure to isolate power lines can result in spurious trip commands or catastrophic card damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48167328088254,"sku":"DS200TCEAG1BRE","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_15-55-10_135bbe34-b70c-4b5f-b4c6-cbcba053a09b.png?v=1784173492","url":"https:\/\/www.autooiltech.com\/es\/products\/ge-ds200tceag1bre-mark-v-emergency-overspeed-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}