{"product_id":"ge-369-hi-r-0-0-0-management-relay","title":"GE 369-HI-R-0-0-0 Management Relay","description":"\u003cp\u003eThe \u003cstrong\u003eGE Multilin 369-HI-R-0-0-0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e369\u003c\/strong\u003e Motor Management Relay, operates as a dedicated hardware component for motor protection, monitoring, and control within industrial motor management systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model number \u003cstrong\u003e369-HI-R-0-0-0\u003c\/strong\u003e defines specific hardware options configured during manufacturing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e369\u003c\/strong\u003e: Base unit platform without basic RTD module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHI\u003c\/strong\u003e: High-voltage control power supply accepting 50-300 VDC or 60-265 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e: Factory-installed internal 12 RTD input hardware card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Standard option without enhanced metering or backspin detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Standard copper communications without fiber optic port interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Base protocol support without auxiliary communication interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Standard conformal coating (no harsh environment treatment).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-R-0-0-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e215 mm x 280 mm x 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 VA maximum (60-265 VAC), 20 W maximum (50-300 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Voltage\u003c\/td\u003e\n\u003ctd\u003e50-300 VDC \/ 60-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e12 built-in RTD channels (100 Ohm Pt, 120 Ohm Ni, 100 Ohm Ni, 10 Ohm Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A \/ 5 A secondary phase CT inputs, ground CT input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relays\u003c\/td\u003e\n\u003ctd\u003e4 form-C output relays (Output 1-4) rated 10 A continuous at 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485 rear port, RS232 front port (Modbus RTU protocol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 369 motor management platform incorporates non-volatile flash memory architecture for field-upgradable operational firmware. Firmware revisions maintain strict backward compatibility across hardware revisions, provided bootloader constraints are met during flash operations. Flash updates occur over the RS485 or RS232 serial interface using standard setup software. Internal memory verification protocols execute automatic checksum validation upon bootup to prevent execution of corrupted code blocks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the input supply parameters for the HI power supply code on the 369-HI-R-0-0-0 relay?\u003c\/p\u003e\n\u003cp\u003eA: The HI control power configuration operates across a universal input range of 50 to 300 VDC or 60 to 265 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003eQ: Can additional RTD channels be added to the 369-HI-R-0-0-0 in the field?\u003c\/p\u003e\n\u003cp\u003eA: The 369-HI-R-0-0-0 includes 12 internal RTD inputs (designated by suffix R). If additional RTD monitoring is required, an external remote RTD module (RRTD) can be connected via the RS485 communication bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Clearance\u003c\/strong\u003e: Secure the relay into a standard panel cutout using supplied mounting hardware. Maintain a minimum vertical clearance of 50 mm above and below the chassis to enable natural thermal convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Connect the rear chassis ground terminal directly to the main station ground bus using low-impedance copper wire (minimum 12 AWG \/ 3.3 mm sq). Terminate all RTD and signal cable shields at the designated relay shield terminal only; leave the remote shield end floating to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Practices\u003c\/strong\u003e: Separate AC control power and CT secondary connections from sensitive analog RTD and communication cables. Ensure all CT secondary circuits remain shorted prior to disconnecting terminal blocks under energized conditions. Maintain at least 5 thread engagement on all screw-type terminal connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eGE IS200SRTDH2A RTD Terminal Board\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS200SRTDH2A\u003c\/strong\u003e is an\u003cstrong\u003e \u003c\/strong\u003eRTD Terminal Board designed for the Mark VIe Distributed Control System (DCS). It provides reliable signal interfacing for resistance temperature detectors (RTDs) used in turbine and industrial process monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100.049%; height: 235.294px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 63.07%; height: 19.6078px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eIS200SRTDH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eRTD Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003e8 RTD inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eDIN‑rail or flat mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eHigh‑density Euro‑block type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eConnects to PRTD or VRTD I\/O packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6078px;\"\u003e\n\u003cth style=\"width: 33.7336%; height: 19.6078px;\"\u003e\u003cstrong\u003eAvailability\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 63.07%; height: 19.6078px;\"\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe IS200SRTDH2A board is a compact RTD terminal interface designed for DIN‑rail or flat mounting. It supports 8 RTD inputs and connects directly to PRTD or VRTD I\/O processors. The board uses Euro‑block type terminal blocks for high‑density wiring, simplifying installation and maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides accurate signal conditioning for RTDs, ensuring precise temperature monitoring in turbine control systems. The board is part of the Mark VIe Speedtronic control platform, which emphasizes modularity and reliability.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTurbine Control\u003c\/strong\u003e: Monitoring turbine temperatures via RTDs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Processes\u003c\/strong\u003e: Accurate temperature measurement in critical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDistributed Control Systems\u003c\/strong\u003e: Integration with Mark VIe I\/O packs for real‑time monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat is the IS200SRTDH2A used for?\u003c\/strong\u003e  It is used to interface RTD sensors with GE Mark VIe control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow many RTDs can it support?\u003c\/strong\u003e  The board supports 8 RTD channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat type of terminal blocks are used?\u003c\/strong\u003e  High‑density Euro‑block type terminals are mounted on the board.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48497499177150,"sku":"369-HI-R-0-0-0","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-11_17-27-56_33f724ff-4985-49c7-bb13-63e8a8350a5a.png?v=1785924394","url":"https:\/\/www.autooiltech.com\/es\/products\/ge-369-hi-r-0-0-0-management-relay","provider":"AutoOilTech Limited","version":"1.0","type":"link"}