{"product_id":"foxboro-i-a-series-fbm211-analog-input-module","title":"Foxboro FBM211 Analog Input Module P0914TN","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Foxboro FBM211 (P0914TN) is a high-density analog input module engineered for the I\/A Series distributed control system. It provides sixteen independent 0 to 20 mA DC input channels, facilitating seamless integration between field instrumentation—such as flow, pressure, and level transmitters—and the system control processor. Engineered for demanding industrial environments, the module prioritizes signal integrity and process reliability through robust galvanic isolation and advanced digital filtering techniques.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSixteen high-resolution 0 to 20 mA DC analog input channels.\u003c\/li\u003e\n\u003cli\u003eIntegrated Sigma-Delta A\/D conversion for superior noise rejection.\u003c\/li\u003e\n\u003cli\u003eSupports redundant operation when paired on a compatible baseplate.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation protects internal logic from field-side electrical interference.\u003c\/li\u003e\n\u003cli\u003eContinuous self-diagnostic monitoring of A\/D performance, memory, and communication health.\u003c\/li\u003e\n\u003cli\u003eRedundant 2 Mbps HDLC fieldbus communication for high-availability data transfer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is frequently deployed in mission-critical process industries, including oil and gas refining, chemical processing, and power generation. It is ideal for monitoring critical process variables where accuracy and high-speed data acquisition are required to maintain loop stability.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM211 (P0914TN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.03% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ohms (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRedundant 2 Mbps HDLC Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 Watts (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before inserting or removing the FBM211 module from the baseplate.\u003c\/li\u003e\n\u003cli\u003eVerify that the baseplate is properly grounded to mitigate electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for field inputs to maintain signal integrity and reduce common-mode noise.\u003c\/li\u003e\n\u003cli\u003eWhen configuring for redundancy, ensure both modules are correctly seated on the designated redundant baseplate slots to enable automatic failover.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation in the cabinet to ensure the module operates within its specified temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes the FBM211 support HART communication?\u003c\/h3\u003e\u003cp\u003eNo, the FBM211 is a standard analog input module designed for 0 to 20 mA signals. For HART-enabled applications, please consult the Foxboro I\/O catalog for compatible HART-specific FBM modules.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with all I\/A Series systems?\u003c\/h3\u003e\u003cp\u003eThe FBM211 is specifically designed for the Series 200 I\/O subsystem. Please confirm your baseplate compatibility and system software revision before installation.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":48825998475454,"sku":"FBM211","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_06a082b4-ecf8-4eef-906f-3f959d35e807.jpg?v=1788279841","url":"https:\/\/www.autooiltech.com\/es\/products\/foxboro-i-a-series-fbm211-analog-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}