{"product_id":"emerson-ve4054s1c0-power-supply","title":"Emerson VE4054S1C0 Power Supply","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson VE4054S1C0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVE4054S1C0\u003c\/strong\u003e System Power Supply, operates as a dedicated hardware component for supplying stable LocalBus logic power within DeltaV M-series Distributed Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4054S1C0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Process Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107 mm x 41 mm x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC (System\/Logic Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Compatibility\u003c\/td\u003e\n\u003ctd\u003eDeltaV LocalBus (S1 Architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Support\u003c\/td\u003e\n\u003ctd\u003eDeltaV Control Network (10\/100BaseT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax LocalBus Length\u003c\/td\u003e\n\u003ctd\u003e6.5 m (21.3 ft) including all cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Integration\u003c\/h3\u003e\n\u003cp\u003eThe VE4054S1C0 ensures systematic, isolated power distribution across the controller and input\/output subsystems to prevent electrical faults from causing system-wide failures.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Parameters:\u003c\/strong\u003e The module features electrical isolation barriers that separate the 12 VDC logic-side bus power from the external 24 VDC field-side instrument power. This galvanic separation prevents high-voltage surges, field-side noise, and ripple from coupling into the controller's central processing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocalBus Power Distribution:\u003c\/strong\u003e Power is injected directly onto the backplane LocalBus. This centralized distribution architecture powers the internal microprocessors and communication circuitry of adjacent I\/O modules, eliminating the requirement for individual external power connections to each module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA and HART Signal Stability:\u003c\/strong\u003e By providing highly regulated DC output rails with minimal high-frequency harmonic distortion, the module maintains a clean, noise-free backplane environment. This prevents signal degradation on sensitive internal buses communicating with multi-drop 4-20 mA HART transmitters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e Can the LocalBus exceed 6.5 meters if high-grade low-attenuation cabling is used?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e No. The total length of the LocalBus, which includes the physical length of all interconnected carrier buses and extension cables, must not exceed 6.5 m (21.3 ft). Exceeding this limit causes unacceptable voltage drops and timing synchronization issues on the bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e Does this power supply module provide loop power for 24 VDC field instruments?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e No. The VE4054S1C0 is designed exclusively to supply 12 VDC logic power to the internal circuitry of the cards and controller. A separate, external 24 VDC power supply must be connected to the field terminal blocks to power transmitters and actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e Is the VE4054S1C0 hot-swappable during system operation?\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The module is designed for online replacement. However, on simplex (non-redundant) power setups, removing the active power supply will immediately cut LocalBus power, shutting down the connected controller and its associated I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Slot Alignment:\u003c\/strong\u003e Guide the module into its designated slot on the power controller carrier. Push firmly until the backplane connectors slide fully together, then tighten the securing screws to prevent vibration-induced contact wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shield Continuity:\u003c\/strong\u003e Ensure the cabinet DIN-rail and carrier assembly are bonded directly to the master instrument grounding bus. Proper low-impedance grounding is critical to allow internal noise filters to route common-mode transients away from the 12 VDC bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow and Thermal Spacing:\u003c\/strong\u003e Maintain clean convective heat pathways above and below the carrier. Do not block the ventilation slots of the module housing to prevent localized thermal buildup, which can degrade the service life of internal electrolytic capacitors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":48167442743486,"sku":"VE4054S1C0","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_17-06-28_d5e0049d-ebbd-4190-a6bc-7982c0d11d11.png?v=1784174677","url":"https:\/\/www.autooiltech.com\/es\/products\/emerson-ve4054s1c0-power-supply","provider":"AutoOilTech Limited","version":"1.0","type":"link"}