{"product_id":"adm52c-s2-yokogawa-digital-output-module","title":"ADM52C S2 Yokogawa Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADM52C S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADM52C S2\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete signal conversion and relay output command execution within CENTUM series DCS networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADM52C S2\u003c\/td\u003e\n\u003ctd\u003e32-Channel Transistor Digital Output Module\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM DCS I\/O Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADM52C...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eDistributed Control System Switching Interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADM52C S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130.0 mm x 25.0 mm x 110.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.0 W nominal (600 mA max at 5.0 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e32 discrete output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eTransistor contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 100 mA (resistive\/inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe ADM52C S2 module integrates robust channel-to-channel isolation architecture to eliminate ground loops and prevent electrical noise propagation between external field actuators and internal CENTUM processor nodes. It processes fast-response transistor switching commands with adjustable pulse width control from 0.1 to 7200 seconds, ensuring precise timing for discrete automation sequences. Furthermore, internal signal conditioning circuitry maintains strict voltage tolerance across 30 VDC contact ratings, protecting downstream switching elements from transient inductive feedback during rapid load de-energization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum contact rating for the transistor outputs on the ADM52C S2 module?\u003c\/p\u003e\n\u003cp\u003eA: Each transistor output channel is rated for a maximum of 30 VDC and 100 mA under resistive or inductive load conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Can the pulse width for the output points be configured in the field?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports adjustable pulse widths ranging from 0.1 to 7200 seconds to accommodate specialized timing requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the node baseplate is completely de-energized before mounting the ADM52C S2 module into the designated CENTUM DCS rack slot. Route external actuator control wiring through dedicated cable ducts, maintaining physical separation from high-voltage power lines to prevent electromagnetic coupling. Verify that terminal block connections are torqued securely and that module retaining screws are fully tightened to maintain reliable backplane edge-connector engagement.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48221445456062,"sku":"ADM52C S2","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ADM12CS2_18ef18cf-a4bb-4309-9c18-e2ac867044e3.png?v=1785291187","url":"https:\/\/www.autooiltech.com\/es\/products\/adm52c-s2-yokogawa-digital-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}