{"product_id":"yokogawa-snt401-53-optical-bus-repeater-module","title":"Yokogawa | SNT401-53 | Optical Bus Repeater Module","description":"\u003ch3\u003e\u003cstrong\u003eDescription：\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Yokogawa \u003cstrong\u003eSNT401‑53\u003c\/strong\u003e is an optical bus repeater module designed for long‑distance ESB bus communication, providing signal regeneration, optical isolation, and stable data transmission for CENTUM control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: SNT401‑53\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: CENTUM VP \/ CS 3000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Optical Bus Repeater Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Extends ESB bus communication distance via optical transmission\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Medium\u003c\/strong\u003e: Optical fiber (single‑mode)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e: 128 Mbps ESB bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOptical Ports\u003c\/strong\u003e: Dual optical ports for redundant or extended links\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Interface\u003c\/strong\u003e: ESB electrical bus input\/output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Optical isolation between electrical and fiber segments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDistance Support\u003c\/strong\u003e: Supports long‑distance ESB communication (kilometer‑scale)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: LED indicators for link status and communication health\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: Supplied via I\/O base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –20 °C to +70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Mounted on Yokogawa ESB\/optical repeater baseplate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOptical Signal Regeneration\u003c\/strong\u003e: Restores ESB bus signals for long‑distance transmission\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Speed ESB Communication\u003c\/strong\u003e: Supports 128 Mbps high‑speed control bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNoise Immunity\u003c\/strong\u003e: Optical isolation eliminates electrical noise interference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRedundant Link Support\u003c\/strong\u003e: Dual optical ports enable redundancy or extended topology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable Integration\u003c\/strong\u003e: Fully compatible with CENTUM VP\/CS 3000 ESB architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Durability\u003c\/strong\u003e: Designed for harsh industrial and long‑distance communication environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":47894823469246,"sku":"SNT401-53","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-17_16-27-16_4f06e225-da1a-4115-97cd-07f089f95cea.png?v=1781747141","url":"https:\/\/www.autooiltech.com\/ar\/products\/yokogawa-snt401-53-optical-bus-repeater-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}