{"product_id":"yokogawa-anb11d-b25-i-o-interface-module","title":"Yokogawa ANB11D-B25 I\/O Interface Module","description":"\u003cp\u003eConfigured for field device data acquisition in Yokogawa process control platforms, the \u003cstrong\u003eYokogawa ANB11D-B25\u003c\/strong\u003e (\u003cstrong\u003eANB11D-B25\u003c\/strong\u003e I\/O Interface Module) provides direct physical\/electrical execution of signal integration and process monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB11D\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Optical ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220 - 240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB11D-B25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact modular form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA (220 - 240 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The interface supports direct integration with HART-enabled field instrumentation, allowing for the transmission of primary process variables and secondary diagnostic data into the control loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The module architecture is designed to manage high-speed digital fieldbus data, facilitating deterministic communication between field sensors and the central control network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The internal circuitry incorporates signal isolation to maintain channel independence, preventing common-mode noise and ground loops from impacting sensitive analog measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The interface provides terminal-level support for CJC, enabling high-precision thermal data acquisition when connected to thermocouple input blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module compatible with existing system backplanes?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for standard modular integration within Yokogawa DCS chassis. Verify backplane power distribution and slot addressing requirements prior to installation.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swapping during normal operation?\u003c\/p\u003e\n\u003cp\u003eA: The design supports standard hot-swap procedures provided the system firmware and chassis configuration allow for online module replacement. Verify the specific system manual for hot-swap capability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module into the designated I\/O slot. Ensure the locking mechanisms are fully engaged to maintain a low-impedance connection with the system backplane and to mitigate the effects of mechanical vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module chassis or the host rack to the cabinet protective earth (PE) bus. A low-impedance ground path is required to maintain EMI\/EMC compliance and ensure the integrity of the analog signal loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Maintain strict segregation between high-voltage power lines and low-level analog signal cables. Use shielded twisted-pair cabling for all field I\/O connections, terminating shields at the designated ground reference points to minimize induced electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48160591773886,"sku":"ANB11D-B25","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-11_15-24-55_33f18be9-cb67-419e-9cd8-247b16bc03fd.png?v=1784007554","url":"https:\/\/www.autooiltech.com\/ar\/products\/yokogawa-anb11d-b25-i-o-interface-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}