{"product_id":"yokogawa-anb10d-420-cu2n-bus-node-unit","title":"Yokogawa ANB10D-420\/CU2N Bus Node Unit","description":"\u003cp\u003eConfigured for field I\/O expansion in CENTUM VP control platforms, the \u003cstrong\u003eYokogawa ANB10D-420\/CU2N\u003c\/strong\u003e (\u003cstrong\u003eANB10D-420\u003c\/strong\u003e ESB Bus Node Unit) provides direct physical\/electrical execution of high-speed bus communication and field device integration.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220 - 240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic model (no explosion protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2N\u003c\/td\u003e\n\u003ctd\u003eConnector Unit for ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-420\/CU2N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount (M5 x 4 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 VA (AC) \/ 5.5 A (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The unit maintains signal path integrity for HART-enabled instrumentation, ensuring that device diagnostic data is processed and relayed to the DCS asset management host without attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The ESB bus architecture supports the deterministic exchange of digital fieldbus data, allowing for seamless integration of smart instrumentation into the process control network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e Internal circuitry provides galvanic isolation between the ESB bus interface and field-connected I\/O modules, protecting the control network from transients and common-mode noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The unit utilizes precision thermal sensing on the terminal boards to execute accurate CJC calculations for thermocouple signals, maintaining measurement precision across the node.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the unit support redundant AC power inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The suffix code \"4\" indicates a dual-redundant power supply configuration, allowing for continuous operation upon the loss of a single power feed.\u003c\/p\u003e\n\u003cp\u003eQ: Is the \/CU2N connector unit sufficient for all ESB bus configurations?\u003c\/p\u003e\n\u003cp\u003eA: The \/CU2N option provides the standard ESB bus connectivity. Ensure that bus terminators are installed as per the specific network topology requirements to prevent signal reflections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the node unit into a standard 19-inch equipment rack using the four M5 screws provided. Ensure the insulation base is installed according to the accessory guidelines to maintain required dielectric clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the node chassis to the cabinet protective earth (PE) bus using a dedicated low-impedance ground cable. A solid ground reference is mandatory for high-speed ESB bus electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the power supply to the redundant input terminals, ensuring proper phasing. Separate ESB bus communication cables from high-voltage AC lines to prevent induced interference and maintain data integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48160590332094,"sku":"ANB10D-420\/CU2N","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/f2ef106c04171e286853c21d0d2b76d7_8d98ca11-cad7-471a-bcfd-3ef8a6ed1b1a.png?v=1784007496","url":"https:\/\/www.autooiltech.com\/ar\/products\/yokogawa-anb10d-420-cu2n-bus-node-unit","provider":"AutoOilTech Limited","version":"1.0","type":"link"}