{"product_id":"yokogawa-anb10d-410-s2-esb-bus-node-interface-unit","title":"Yokogawa ANB10D-410\/S2 ESB Bus Node Interface Unit","description":"\u003cp\u003eConfigured for high-speed I\/O integration in CENTUM distributed control systems, the \u003cstrong\u003eYokogawa ANB10D-410\/S2\u003c\/strong\u003e (\u003cstrong\u003eANB10D\u003c\/strong\u003e) Node Unit provides direct physical\/electrical execution of ESB bus data transmission, dual-redundant communication path management, and signal bridging for local I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eNode unit for Dual-Resistant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003ePrimary AC\/DC power variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/S2\u003c\/td\u003e\n\u003ctd\u003eS2 revision hardware iteration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-410\/S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 x 20.3 x 14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 VA (AC) \/ 15 W (DC logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e10 I\/O connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eYokogawa DCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The ANB10D serves as the interface node for field control stations that aggregate HART diagnostic data. This connectivity is mandatory to ensure transparent passthrough of HART signal overlays from field instrumentation to the DCS engineering environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The unit acts as the primary backplane interface for fieldbus-connected subsystems within the ESB architecture. This connectivity is mandatory to provide the deterministic bandwidth required for fieldbus segment communication and I\/O synchronization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The internal circuitry incorporates galvanic isolation between the ESB bus transceiver and the node power supply. This is mandatory to prevent ground potential differences between remote racks from inducing common-mode noise into the communication backbone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The node unit maintains precise thermal management for the internal bus controllers, which is mandatory to prevent clock drift and timing errors that could otherwise result in ESB bus communication timeouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the ANB10D-410\/S2 compatible with existing CENTUM VP rack installations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 5.1 x 20.3 x 14.6 cm form factor is designed for standard CENTUM rack integration. However, verification of backplane slot availability and the specific Field Control Unit (FCU) firmware revision is mandatory before installation to ensure system-level recognition.\u003c\/p\u003e\n\u003cp\u003eQ: Can the dual-redundant power supplies be managed independently?\u003c\/p\u003e\n\u003cp\u003eA: The -4 configuration supports dual-redundant power inputs. Maintaining separate power paths for each input is mandatory to maximize system availability; failure of one path will result in an automatic switchover to the backup source without interrupting node communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the node unit securely into the designated rack slot. Ensuring the faceplate is flush against the enclosure is mandatory to meet environmental protection standards and to prevent mechanical strain on the unit housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate the node chassis to the cabinet’s central safety earth bus. A low-impedance connection is mandatory to provide effective EMI\/RFI shielding and to ensure the ESB communication interface remains free from electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect control signals using appropriately rated cabling. Keep signal cabling physically separated from high-voltage AC lines by at least 150 mm; this isolation is mandatory to prevent inductive noise injection into the serial communication link.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48078473068734,"sku":"ANB10D-410\/S2","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_16-40-23_602c585e-61a0-4ad3-a672-2a17f676c9a2.png?v=1783590517","url":"https:\/\/www.autooiltech.com\/ar\/products\/yokogawa-anb10d-410-s2-esb-bus-node-interface-unit","provider":"AutoOilTech Limited","version":"1.0","type":"link"}