{"product_id":"yokogawa-amm21t-thermocouple-input-multiplexer-module","title":"Yokogawa AMM21T Thermocouple Input Multiplexer Module","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Yokogawa \u003cstrong\u003eAMM21T\u003c\/strong\u003e is a thermocouple input multiplexer module designed for high‑density temperature signal acquisition across multiple TC types in CENTUM VP and ProSafe‑RS systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Yokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e AMM21T\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Thermocouple Input Multiplexer Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e 16 multiplexed TC inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported TC Types\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e J, K, T, E, R, S, B, N\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Low‑level mV signals (TC‑specific)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e High‑accuracy, low‑noise conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Integrated CJC for stable temperature measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Channel‑to‑system isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e CENTUM VP \/ ProSafe‑RS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Rack‑mounted module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Terminal‑based TC connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Industrial operating range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Density TC Inputs\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Supports 16 multiplexed thermocouple channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccurate Temperature Measurement\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e High‑precision mV conversion with CJC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNoise‑Resistant Design\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Isolated channels improve signal integrity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible Configuration\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e TC type and range set via system software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable DCS Integration\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Fully compatible with Yokogawa control platforms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEasy Maintenance\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e Modular structure simplifies replacement and servicing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":47901319528638,"sku":"AMM21T","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/AMM22T_2.png?v=1780036462","url":"https:\/\/www.autooiltech.com\/ar\/products\/yokogawa-amm21t-thermocouple-input-multiplexer-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}