{"product_id":"yokogawa-adv159-p00-digital-i-o-modules","title":"Yokogawa ADV159-P00 Digital I\/O Modules","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV159-P00\u003c\/strong\u003e serves as the primary \u003cstrong\u003eADV159\u003c\/strong\u003e Digital I\/O Modules utilized to execute 32-channel input and transistor contact output tasks across distributed control network platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Suffix Code Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDesignation \u0026amp; Specification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV159\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module (32-channel input, transistor contact output, isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003ePushbutton input function supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eStandard configuration build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type standard version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV159-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan \/ Authorized Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa Modular Rack Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial rack rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e330 mA (5 V DC) maximum current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of I\/O Channels\u003c\/td\u003e\n\u003ctd\u003e32-channel input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Input OFF Signal\u003c\/td\u003e\n\u003ctd\u003e100 kΩ or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Input ON Signal\u003c\/td\u003e\n\u003ctd\u003e200 Ω or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input OFF Signal\u003c\/td\u003e\n\u003ctd\u003e4.5 to 25 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Rating\u003c\/td\u003e\n\u003ctd\u003e30 V DC, 100 mA (inductive load, resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Instrumentation and Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module executes isolated channel signal processing, ensuring robust galvanic separation boundaries across complex process loops. Internal circuit architectures maintain stable common-mode signal integrity and precise threshold detection for both contact and voltage inputs.\u003c\/p\u003e\n\u003cp\u003eOutput signal switching is handled via transistor contacts capable of driving resistive and inductive loads up to 30 V DC and 100 mA, while response timing is governed by fixed internal polling parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the input signal resistance thresholds for contact status detection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Contact OFF signals require 100 kΩ or more, whereas ON signals require 200 Ω or less, with a minimum current value of 1.25 mA when the contact is short-circuited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specifications govern the transistor contact output ratings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The output signal uses a transistor contact supporting inductive and resistive loads rated at 30 V DC and 100 mA, with an output response time of 16 ms or less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module interface with external field connections?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: External connections are established using a dedicated cable (KS2), and the hardware is designed to be compatible with ST3 systems.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module firmly into the designated modular rack slot to guarantee proper backplane bus pin engagement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route digital input and transistor output signal lines away from high-power distribution cables to prevent electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect all cable shield drains to the designated grounding bar inside the termination cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Inspect terminal connections and verify signal voltage ranges prior to system energization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48231089963198,"sku":"ADV159-P00","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-11_15-35-56_e26eade9-a39a-407e-98dd-c761c5b9b853.png?v=1785396110","url":"https:\/\/www.autooiltech.com\/ar\/products\/yokogawa-adv159-p00-digital-i-o-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}