{"product_id":"yokogawa-adv151-p13-digital-input","title":"Yokogawa ADV151-P13 Digital Input","description":"\u003cp\u003eConfigured for discrete signal data acquisition in distributed control system platforms, the \u003cstrong\u003eYokogawa ADV151-P13\u003c\/strong\u003e (\u003cstrong\u003eADV151-P13\u003c\/strong\u003e Digital Input Module) provides direct physical and electrical execution for up to 32 parallel contact or voltage status inputs operating at 24 V DC.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan \/ Global Manufacturing Plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa centum VP card form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 120 mA (5 V DC system internal bus), 24 V DC external loop power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels, sink\/source isolated in groups of 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal (18-26.4 V DC ON state, \u0026lt;=5 V DC OFF state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/-20% per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (Signal to System, 1 min), 500 V AC (Commons per 16 ch, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=8 ms (OFF to ON \/ ON to OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Isolation and Channel Grouping\u003c\/h3\u003e\n\u003cp\u003eOperating within industrial distributed control system architectures, the module integrates galvanic isolation across dual 16-channel common groups, suppressing ground loops and common-mode transient interference. Channel-to-system dielectric strength withstands 2 kV AC potential barriers for 1 minute, preventing field-side electrical surges from propagating into internal system buses. Input thresholds maintain deterministic response characteristics with an ON voltage threshold span of 18 to 26.4 V DC and an OFF state ceiling of 5 V DC, ensuring noise immunity in high electromagnetic interference environments. Minimum ON detection time is fixed at 20 ms to filter out contact bounce from mechanical switches.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum switching frequency supported by the ADV151-P13 input channels?\u003c\/p\u003e\n\u003cp\u003eA: The maximum ON\/OFF cycle frequency for input states is limited to 25 Hz to ensure reliable debounce processing and hardware register latching.\u003c\/p\u003e\n\u003cp\u003eQ: How are the 32 input channels grouped for power supply and commons?\u003c\/p\u003e\n\u003cp\u003eA: The 32 channels are isolated in two common groups of 16 channels each, allowing separate external power supply configurations while maintaining a 500 V AC dielectric isolation barrier between groups.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swap capability supported during runtime rack maintenance?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is supported when executing module replacement procedures under controlled system redundancy states, provided that terminal blocks are mechanically secured and system software acknowledges node isolation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the ADV151-P13 module onto standard Yokogawa node unit base plates or remote node units using the designated locking mechanism. Ensure all field wiring shields are grounded at a single point to prevent electromagnetic coupling. Verify that external loop power supplies deliver a stable 24 V DC within the specified 18-26.4 V DC tolerance range prior to terminal block connection. Inspect terminal screws for correct torque ratings to prevent intermittent contact resistance under vibration conditions.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48230988775614,"sku":"ADV151-P13","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-11_15-24-55_cd222a65-372c-438e-bc2e-051669b4efd1.png?v=1785396117","url":"https:\/\/www.autooiltech.com\/ar\/products\/yokogawa-adv151-p13-digital-input","provider":"AutoOilTech Limited","version":"1.0","type":"link"}