{"product_id":"snt501-13-yokogawa-optical-esb-bus-repeater-slave-module","title":"SNT501-13 | Yokogawa | Optical ESB Bus Repeater Slave Module","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Yokogawa \u003cstrong\u003eSNT501‑13\u003c\/strong\u003e Optical ESB Bus Repeater Slave Module converts electrical ESB bus signals to optical transmission for long‑distance communication within CENTUM VP and ProSafe‑RS systems. As the slave‑side repeater, it pairs with a master repeater to extend ESB segments while maintaining signal integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Yokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: SNT501‑13\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Optical ESB Bus Repeater (Slave Module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: CENTUM VP \/ ProSafe‑RS ESB bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Electrical‑to‑optical ESB signal conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Medium\u003c\/strong\u003e: Fiber‑optic ESB communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRole\u003c\/strong\u003e: Slave‑side repeater paired with master repeater\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDistance Extension\u003c\/strong\u003e: Supports long‑range ESB communication beyond electrical limits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNoise Immunity\u003c\/strong\u003e: Optical medium eliminates EMI and improves stability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Built‑in communication and module health monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e: Rack‑mounted module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: −20°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOptical ESB Transmission\u003c\/strong\u003e: Converts ESB electrical signals to optical format\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSlave‑Side Operation\u003c\/strong\u003e: Designed for the slave end of extended ESB segments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNoise‑Free Communication\u003c\/strong\u003e: Optical medium eliminates EMI and improves reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExtended ESB Reach\u003c\/strong\u003e: Supports cabinet‑to‑cabinet and building‑to‑building ESB networking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdvanced Diagnostics\u003c\/strong\u003e: Monitors communication status and module health\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCENTUM\/ProSafe‑RS Integration\u003c\/strong\u003e: Fully compatible with Yokogawa ESB node architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ – Common Questions\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat_is_the_SNT501-13_for\u003c\/strong\u003e: It converts ESB electrical signals to optical transmission on the slave side.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs_it_compatible_with_CENTUM_VP\u003c\/strong\u003e: Yes, it works with CENTUM VP and ProSafe‑RS ESB networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhy_use_optical_ESB\u003c\/strong\u003e: Optical ESB reduces noise and supports long‑distance communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes_it_support_redundant_paths\u003c\/strong\u003e: It can be used within redundant ESB designs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs_it_slave_or_master\u003c\/strong\u003e: SNT501‑13 is the slave‑side repeater module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48029686268094,"sku":"SNT501-13","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-17_16-27-16_4f06e225-da1a-4115-97cd-07f089f95cea.png?v=1781747141","url":"https:\/\/www.autooiltech.com\/ar\/products\/snt501-13-yokogawa-optical-esb-bus-repeater-slave-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}