{"product_id":"rb301-yokogawa-s2-rio-bus-interface-master-card","title":"RB301 | Yokogawa | S2 RIO Bus Interface Master Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYokogawa RB301\u003c\/strong\u003e, also cataloged as the\u003cstrong\u003e \u003c\/strong\u003eS2 RIO Bus Interface Master Card, is a dedicated communication module designed for Remote I\/O (RIO) bus interfacing within Yokogawa’s CENTUM control systems. It serves as the master interface card, enabling seamless communication between the control processor and distributed I\/O subsystems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Yokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct No.:\u003c\/strong\u003e RB301\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e S2 RIO Bus Interface Master Card\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Remote I\/O bus communication for CENTUM systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBus Type:\u003c\/strong\u003e RIO (Remote I\/O) S2 interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Optical isolation for signal integrity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed:\u003c\/strong\u003e High‑speed bus communication (128 Mbps typical for ESB\/RIO systems)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Dedicated backplane and bus connectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e CENTUM VP and CENTUM CS 3000 series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Supports dual‑redundant bus configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e ~1.5 Kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaster Bus Interface:\u003c\/strong\u003e Acts as the central controller for RIO bus communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Speed Data Transfer:\u003c\/strong\u003e Ensures deterministic communication between I\/O subsystems and control processors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOptical Isolation:\u003c\/strong\u003e Provides robust protection against electrical noise and interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Operates in simplex or dual‑redundant configurations for fault tolerance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Designed for seamless operation within Yokogawa CENTUM VP architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the primary function of the RB301? A: It serves as the master card for S2 RIO bus communication, linking control processors with distributed I\/O.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Does the RB301 support redundancy? A: Yes, it supports dual‑redundant bus configurations for enhanced reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Which systems are compatible with the RB301? A: It is compatible with Yokogawa CENTUM VP and CENTUM CS 3000 series control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMount the RB301 securely within the designated rack slot.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure proper seating of bus connectors to maintain communication integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain separation between bus cabling and high‑voltage wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify redundancy configuration during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePerform diagnostic checks to confirm stable RIO bus communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":47624799322302,"sku":"RB301","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/RB301_3.jpg?v=1781244923","url":"https:\/\/www.autooiltech.com\/ar\/products\/rb301-yokogawa-s2-rio-bus-interface-master-card","provider":"AutoOilTech Limited","version":"1.0","type":"link"}