{"product_id":"is400tcath1a-ge-core-analog-terminal-board","title":"IS400TCATH1A | GE | Core Analog Terminal Board","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE\u003cstrong\u003e IS400TCATH1A\u003c\/strong\u003e Core Analog Terminal Board provides analog‑signal landing and routing for Mark VIe systems, supporting stable field interfacing and direct connection to associated processing boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: IS400TCATH1A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e: Core Analog Terminal Board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: GE Mark VIe control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e: Analog field inputs and conditioned analog routing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e: P1\/P2 connectors for TCAT cable interfacing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e: Bulk 28 VDC via P5 connector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Routing\u003c\/strong\u003e: Provides P4 output to JGPA shield termination board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProcessing Board Interface\u003c\/strong\u003e: Routes signals to BCAA and BCAB boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e: Designed for simplex applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e: Pluggable terminal blocks for field wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: Field analog landing, shield termination, signal routing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Signal Routing\u003c\/strong\u003e: Direct PCB‑trace routing to BCAA\/BCAB processing boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTCAT Connectivity\u003c\/strong\u003e: Provides P1\/P2 68‑pin connectors for TCAT cable sets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShield Termination\u003c\/strong\u003e: Supports proper grounding via JGPA termination path\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePluggable Terminals\u003c\/strong\u003e: Allows fast field wiring and maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSimplex Architecture\u003c\/strong\u003e: Optimized for non‑redundant Mark VIe installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStable Integration\u003c\/strong\u003e: Ensures predictable analog‑signal behavior within Mark VIe systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ – Common Questions\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat does IS400TCATH1A do\u003c\/strong\u003e: It provides analog‑signal landing and routing to processing boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes it support TCAT boards\u003c\/strong\u003e: Yes, via P1 and P2 68‑pin connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs it redundant\u003c\/strong\u003e: No, it is designed for simplex configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes it include terminal blocks\u003c\/strong\u003e: Yes, pluggable terminal blocks are provided.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow is power handled\u003c\/strong\u003e: Bulk 28 VDC enters via P5 and is routed to JGPA through P4.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48157279453374,"sku":"IS400TCATH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is400tdbth2a-static-sensitive-board-5rephwrzmfh.png?v=1759044291","url":"https:\/\/www.autooiltech.com\/ar\/products\/is400tcath1a-ge-core-analog-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}