{"product_id":"is200tcath1aba-ge-thermocouple-input-terminal-module","title":"IS200TCATH1ABA | GE | Thermocouple Input Terminal Module","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eIS200TCATH1ABA\u003c\/strong\u003e Thermocouple Input Terminal Module provides conditioned thermocouple signal inputs for Mark VIe turbine control systems, ensuring accurate temperature measurement and reliable signal routing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: IS200TCATH1ABA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: Mark VIe\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Thermocouple input terminal module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e: Supports multiple thermocouple types\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: Multi‑channel thermocouple input capability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e: Cold‑junction compensation and filtering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e: 68‑pin connectors for I\/O pack interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: Low‑voltage control power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: Suitable for turbine control environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Designed for GE Mark VIe I\/O packs and control modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccurate Temperature Input\u003c\/strong\u003e: Provides stable and precise thermocouple signal acquisition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNoise Filtering\u003c\/strong\u003e: Input filtering reduces electrical noise for reliable readings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCold‑Junction Compensation\u003c\/strong\u003e: Ensures accurate thermocouple measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRobust Construction\u003c\/strong\u003e: Industrial‑grade design for turbine control environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDirect I\/O Pack Interface\u003c\/strong\u003e: Connects directly to Mark VIe I\/O packs via 68‑pin connectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSecure Terminal Blocks\u003c\/strong\u003e: Screw‑type terminals ensure stable wiring connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ – Common Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat_is_TCATH\u003c\/strong\u003e: TCATH is a thermocouple input terminal module used for temperature signal acquisition in GE Mark VIe systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs_it_interchangeable\u003c\/strong\u003e: IS200TCATH1ABA should be used only with compatible Mark VIe I\/O packs; interchangeability is limited.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow_to_connect_thermocouples\u003c\/strong\u003e: Wire thermocouples to the terminal blocks following polarity markings and tighten screws securely.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental_limits\u003c\/strong\u003e: Operate within GE‑specified turbine control ambient conditions for best performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47975029342398,"sku":"IS200TCATH1ABA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200trlyh1bge-relay-output-board-uyvour4wj4n.png?v=1759055679","url":"https:\/\/www.autooiltech.com\/ar\/products\/is200tcath1aba-ge-thermocouple-input-terminal-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}