{"product_id":"is200epctg1azz-ge-circuit-board","title":"IS200EPCTG1AZZ | GE | Circuit Board","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eIS200EPCTG1AZZ\u003c\/strong\u003e Circuit Board is an excitation‑processing and control‑interface PCB used in Mark VI turbine systems, supporting stable signal conditioning, regulated excitation control, and reliable communication with GE control architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: IS200EPCTG1AZZ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: Mark VI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e: Excitation processing and control interface PCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Excitation regulation, analog signal conditioning, control interfacing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e: Multilayer PCB with high‑density components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eComponents\u003c\/strong\u003e: ICs, resistors, capacitors, connectors, power‑conditioning elements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e: High‑speed Mark VI backplane communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: GE Mark VI turbine and generator control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e: Regulated low‑voltage supply from Mark VI rack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to +60°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e: Rack‑mounted module within Mark VI chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExcitation Processing\u003c\/strong\u003e: Supports regulated excitation control for turbine and generator systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStable Signal Conditioning\u003c\/strong\u003e: Ensures accurate analog signal handling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMark VI Integration\u003c\/strong\u003e: Fully compatible with GE Mark VI architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Speed Communication\u003c\/strong\u003e: Backplane interface supports fast control‑system data exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Reliability\u003c\/strong\u003e: Built for continuous operation in harsh turbine environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaintenance‑Friendly\u003c\/strong\u003e: Supports quick board replacement without wiring changes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ – Common Questions\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat_is_the_IS200EPCTG1AZZ_for\u003c\/strong\u003e: It handles excitation processing and signal conditioning in Mark VI systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs_it_compatible_with_Mark_VI\u003c\/strong\u003e: Yes, it is designed for GE Mark VI turbine‑control architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes_it_support_high‑speed_data\u003c\/strong\u003e: Yes, it uses high‑speed backplane communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCan_it_be_replaced_easily\u003c\/strong\u003e: Yes, it supports quick module swap procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48025701712062,"sku":"IS200EPCTG1AZZ","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200emcsg1aa-exciter-multibridge-conduction-sensor-card-2fqgzos4032.png?v=1759055412","url":"https:\/\/www.autooiltech.com\/ar\/products\/is200epctg1azz-ge-circuit-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}