{"product_id":"is200acleh1a-ge-application-control-layer-module","title":"IS200ACLEH1A | GE | Application Control Layer Module","description":"\u003ch2\u003eGE IS200ACLEH1A Application Control Layer Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for processor‑level control execution in EX2100 excitation networks, the \u003cstrong\u003eGE IS200ACLEH1A\u003c\/strong\u003e (\u003cstrong\u003eIS200ACLEH1A\u003c\/strong\u003e Application Control Layer Module) provides deterministic CPU, PCI, Ethernet, and ISBus processing across fixed backplane interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS200ACLEH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e2.90 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eEX2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eApplication Control Layer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e486 CPU, 100 MHz, 16 KB L1 cache\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e128 KB L2 cache, 8 MB DRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFlash BIOS\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e4 MB (Primary BIOS, Config Utility, GE Extended BIOS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eCOM1, COM2, Ethernet, ISBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBackplane Connector\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eP1, 4‑row 128‑pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eTwo half‑slots in Innovation Series or EX2100 racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePCI\/ISA Bridge\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eInterrupt routing, RTC, DMA controllers, system clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eReset Logic\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eFront‑panel reset switch tied to RESDRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eToolbox Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePcode configuration, firmware upgrades, parameter monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eWithin EX2100 architectures, the ACLE module aligns with deterministic Ethernet and ISBus timing required for synchronous controller execution. The PCI controller manages memory and I\/O transfers with fixed‑cycle behavior, ensuring predictable propagation of configuration and runtime data. Firmware flash compatibility is maintained through GE’s extended BIOS, allowing serial loader updates without EPROM replacement. I\/O density scaling is achieved through backplane‑level expansion, while the ACLE hardware maintains constant communication velocity across all variants.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IS200ACLEH1A be hot‑swapped?\u003c\/strong\u003e A: No. The module must be removed only when the associated EX2100 segment is de‑energized to avoid transient loading on backplane power rails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ACLE impose additional backplane current load?\u003c\/strong\u003e A: The module draws power through the P1 connector. Its consumption is within standard EX2100 controller limits and does not require special provisioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does firmware compatibility affect operation?\u003c\/strong\u003e A: Firmware must match the controller’s supported BIOS and Pcode sets. Mismatched firmware may prevent proper initialization or communication over Ethernet and ISBus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the EX2100 cabinet is fully de‑energized before handling the module.\u003c\/li\u003e\n\u003cli\u003eSeat the P1 connector firmly to maintain deterministic backplane communication.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between Ethernet cabling and ISBus wiring to reduce noise coupling.\u003c\/li\u003e\n\u003cli\u003eGround shielded cables at a single termination point to avoid ground‑loop interference.\u003c\/li\u003e\n\u003cli\u003eVerify reset‑switch functionality after installation to ensure proper RESDRV signaling.\u003c\/li\u003e\n\u003cli\u003eUse the GE Control Systems Toolbox to validate Pcode loading and runtime parameter access.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48164561060030,"sku":"IS200ACLEH1A","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200aepah1abb-optional-auxiliary-board-jot5ld0gdsz.png?v=1759044649","url":"https:\/\/www.autooiltech.com\/ar\/products\/is200acleh1a-ge-application-control-layer-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}