{"product_id":"ic752spl014-ge-ex2100-operator-interface","title":"GE Fanuc IC752SPL014 EX2100 Operator Interface Terminal","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThe IC752SPL014 is a robust Operator Interface Terminal (OIT) engineered specifically for the GE EX2100 Excitation Control System. This unit functions as the primary human-machine interface for power generation control, enabling precise management of synchronous generator excitation. It is widely utilized in hydro, thermal, and combined-cycle power plants to provide operators with real-time status updates, alarm management, and control over excitation bridge parameters. By facilitating rapid access to system diagnostics, the terminal plays a vital role in maintaining generator stability and minimizing downtime during grid-related events.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for seamless integration with the EX2100 Excitation Control architecture.\u003c\/li\u003e\n\u003cli\u003eFacilitates direct monitoring of critical excitation parameters including field voltage, field current, and reactive power compensation.\u003c\/li\u003e\n\u003cli\u003eRuggedized chassis construction specifically suited for high-vibration power plant environments.\u003c\/li\u003e\n\u003cli\u003eProvides centralized diagnostic reporting and alarm annunciation for rapid fault isolation.\u003c\/li\u003e\n\u003cli\u003eSupports real-time communication with the Excitation Control Board (ECB) and associated digital regulation modules.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe IC752SPL014 is intended for deployment within excitation control cabinets. Its primary applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSynchronous generator excitation regulation.\u003c\/li\u003e\n\u003cli\u003ePower generation control and monitoring.\u003c\/li\u003e\n\u003cli\u003eReal-time diagnostic data display for excitation bridges.\u003c\/li\u003e\n\u003cli\u003eOperational adjustment of generator transient stability parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC752SPL014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eEX2100 Excitation Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Terminal (OIT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e14.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDedicated EX2100 Serial\/Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the unit is installed in a clean, dry, and climate-controlled environment within the excitation enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify that the mounting surface is secure to prevent excessive vibration transmission to the display electronics.\u003c\/li\u003e\n\u003cli\u003eAlways disconnect power supply to the EX2100 cabinet before attempting to install or remove the interface module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the chassis to the cabinet earth bus to mitigate EMI interference.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables away from high-voltage power lines to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC752SPL014?\u003c\/h3\u003e\u003cp\u003eThe IC752SPL014 serves as an operator interface for the GE EX2100 system, allowing technicians to monitor and adjust excitation parameters for generators in real-time.\u003c\/p\u003e\u003ch3\u003eIs this unit compatible with other GE systems?\u003c\/h3\u003e\u003cp\u003eThe IC752SPL014 is specifically designed for the EX2100 Excitation Control series and is optimized for its communication protocols and hardware architecture.\u003c\/p\u003e\u003ch3\u003eWhat should I do if the display does not show data?\u003c\/h3\u003e\u003cp\u003eVerify the physical connection to the EX2100 controller, check that the communication link is active, and ensure the unit is receiving the correct voltage from the excitation control bus.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":48845788610750,"sku":"IC752SPL014","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_e5f8f8b5-cac3-4c74-acee-4ecb27da0ad2.jpg?v=1788661044","url":"https:\/\/www.autooiltech.com\/ar\/products\/ic752spl014-ge-ex2100-operator-interface","provider":"AutoOilTech Limited","version":"1.0","type":"link"}