{"product_id":"honeywell-mu-taih03-51309136-125-high-level-analog-input-module","title":"Honeywell MU-TAIH03 51309136-125 High Level Analog Input Module","description":"\u003ch1\u003eHoneywell MU-TAIH03 51309136-125 High Level Analog Input Module\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell MU-TAIH03 51309136-125\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-TAIH03\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware interface for high-level analog signal acquisition within Honeywell process control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMU-TAIH03 (51309136-125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eStandard I\/O module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eControl-room ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eHigh-level analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eHigh-level analog signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eCE-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eProcess variable acquisition, actuator feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4–20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe MU-TAIH03 supports standard 4–20 mA analog loop signaling for high-level process variable acquisition. Integration with HART-enabled devices allows diagnostic feedback and loop validation. Channel-to-channel isolation ensures stable input performance, while conformal coating provides environmental protection against humidity and dust.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: Does the MU-TAIH03 support redundant operation? A: No, this module is designed for non-redundant configurations; redundancy must be implemented at the controller level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the module be hot-swapped during system operation? A: No, removal or insertion must be performed with the system powered down to maintain loop integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How is channel isolation achieved? A: Each analog input channel is electrically isolated to prevent cross-channel interference and maintain signal accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the module within the designated cabinet slot, ensuring full connector engagement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e: Route analog loop wiring separately from high-current conductors to minimize induced noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e: Ground cable shields at a single point to prevent circulating currents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVerification\u003c\/strong\u003e: Confirm 4–20 mA loop calibration during commissioning using a loop calibrator.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e: Inspect terminals periodically for secure connections and signs of thermal stress.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48419204104382,"sku":"MU-TAIH03 51309136-125","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/honeywell-mc-taih02-51304453-150-analog-input-sti-fta-module-4bigxnxbq4s.png?v=1775637499","url":"https:\/\/www.autooiltech.com\/ar\/products\/honeywell-mu-taih03-51309136-125-high-level-analog-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}