{"product_id":"honeywell-mp-xlad05-100-industrial-storage-module","title":"Honeywell MP-XLAD05-100 Industrial Storage Module","description":"\u003cp\u003eConfigured for data storage in industrial control platforms, the \u003cstrong\u003eHoneywell MP-XLAD05-100\u003c\/strong\u003e (\u003cstrong\u003eMP-XLAD05-100\u003c\/strong\u003e Storage Module) provides direct physical\/electrical execution of non-volatile data retention and high-speed retrieval within embedded computing systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMP-XLAD05-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eIndustrial HDD form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eController bus dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Capacity\u003c\/td\u003e\n\u003ctd\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Data Acquisition and Integrity Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The storage module interfaces with control systems that log data from 4-20 mA HART instrumentation. It maintains the data integrity of diagnostic parameters retrieved from field devices during continuous process monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The module is designed to log telemetry data from FOUNDATION Fieldbus or Profibus PA segments. It facilitates the buffering of process variables and asset management data within the DCS controller environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The electrical interface ensures that the storage bus maintains isolation from sensitive analog input loops, preventing ground noise or transient surges from the backplane from corrupting stored diagnostic registers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The module is optimized for environments where process controllers perform thermocouple input processing. It ensures that data logging operations remain unaffected by the thermal fluctuations associated with local CJC hardware on neighboring I\/O cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the MP-XLAD05-100 hot-swappable in a running controller chassis?\u003c\/p\u003e\n\u003cp\u003eA: No, this storage module is not hot-swappable. The system power must be cycled and the controller placed in a maintenance state before the module is extracted to prevent data corruption or backplane pin damage.\u003c\/p\u003e\n\u003cp\u003eQ: Does this drive require specific firmware configuration upon installation?\u003c\/p\u003e\n\u003cp\u003eA: The module functions as a standard storage interface. Ensure the host controller BIOS or system configuration software is set to recognize the storage geometry and partition table format appropriate for the target industrial OS.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the drive within the designated drive bay or mounting bracket provided in the controller chassis. Ensure that vibration-damping hardware is utilized if the system is located near high-speed rotating equipment or reciprocating machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the drive chassis is electrically bonded to the controller backplane or the cabinet's internal ground rail. A proper ground path is mandatory to prevent electrostatic discharge (ESD) from damaging the internal controller logic during insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Keep SATA\/IDE and power cabling away from high-voltage AC lines or EMI-emitting cabling. Maintain a minimum separation of 150 mm to prevent electromagnetic crosstalk from interfering with high-speed read\/write operations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48006427312318,"sku":"MP-XLAD05-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/22_27e86309-58d3-4997-bcc6-34e09d39f98c.png?v=1783481734","url":"https:\/\/www.autooiltech.com\/ar\/products\/honeywell-mp-xlad05-100-industrial-storage-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}