{"product_id":"honeywell-mc-taox02-51304476-175-analog-output-fta","title":"Honeywell MC-TAOX02 51304476-175 Analog Output FTA","description":"\u003ch1\u003eHoneywell MC-TAOX02 51304476-175 Analog Output FTA\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell MC-TAOX02 51304476-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-TAOX02\u003c\/strong\u003e Analog Output FTA, operates as a dedicated field termination assembly for 4–20 mA analog signal drive within Experion and TDC control platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMC-TAOX02 (51304476-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e0.44 lbs (0.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eStandard FTA form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePassive FTA, powered via controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e8 analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eCE-compliant, conformally coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNon-redundant configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eValve actuation, proportional load drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4–20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe MC-TAOX02 supports standard 4–20 mA analog loop signaling for proportional control of valves and actuators. Channel-to-channel isolation is maintained through the FTA design, ensuring stable loop performance. Integration with HART-enabled devices allows diagnostic feedback and loop validation, while conformal coating provides environmental protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: Does the MC-TAOX02 support redundant operation? A: No, this FTA is designed for non-redundant configurations only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the typical load compliance for the 4–20 mA outputs? A: Compliance is determined by the controller’s AO drive; the FTA provides termination and isolation only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the FTA be hot-swapped during operation? A: No, removal or insertion must be performed with the system powered down to maintain loop integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the FTA within the designated cabinet slot, ensuring full connector engagement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e: Route analog loop wiring separately from high-current conductors to minimize induced noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e: Ground cable shields at a single point to prevent circulating currents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVerification\u003c\/strong\u003e: Confirm 4–20 mA loop calibration during commissioning using a loop calibrator.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Care\u003c\/strong\u003e: Ensure conformal coating remains intact; avoid exposure to solvents or abrasive cleaning agents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48411670216894,"sku":"MC-TAOX02 51304476-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/honeywell-mu-taox02-51304476-125-analog-output-termination-board-saq3vmqi21a_1a4567b3-82e9-4766-a8b9-04ad0c9bb71a.png?v=1758876880","url":"https:\/\/www.autooiltech.com\/ar\/products\/honeywell-mc-taox02-51304476-175-analog-output-fta","provider":"AutoOilTech Limited","version":"1.0","type":"link"}