{"product_id":"honeywell-fc-pdb-0824p-power-distribution-board","title":"Honeywell FC-PDB-0824P Power Distribution Board 24Vdc 8-Channel","description":"\u003cp\u003eThe Honeywell FC-PDB-0824P is a robust power distribution board engineered for the Safety Manager system, facilitating the efficient routing of 24Vdc power from a primary rail to various cabinet-mounted devices. This module provides a centralized interface for powering field termination assemblies (FTAs), fan units, and other critical instrumentation within industrial enclosures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight independent 24Vdc output channels.\u003c\/li\u003e\n\u003cli\u003eIntegrated 2A slow-acting fuse (5x20mm) protection for each channel to isolate faults.\u003c\/li\u003e\n\u003cli\u003eKeyed 2-pole input header (Weidmuller BVZ 7.62HP\/02F SN) to prevent incorrect polarity or insertion.\u003c\/li\u003e\n\u003cli\u003eConformal coated (CC) circuitry for enhanced resilience in industrial environments.\u003c\/li\u003e\n\u003cli\u003eDIN-rail mountable design for streamlined cabinet integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS) and Safety Manager architectures.\u003c\/li\u003e\n\u003cli\u003eRemote I\/O power management in oil, gas, and petrochemical facilities.\u003c\/li\u003e\n\u003cli\u003eCentralized power distribution for process automation and industrial control cabinets.\u003c\/li\u003e\n\u003cli\u003eAuxiliary power management for cabinet cooling and field sensor loops.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-PDB-0824P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e2A per channel (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003e2 AT (slow acting), 5x20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eWeidmuller BVZ 7.62HP\/02F SN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connectors\u003c\/td\u003e\n\u003ctd\u003eWeidmuller BLZ 5.08\/2F SN SW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTS32 \/ TS35 x 7.5 DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (CC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the cabinet power is fully disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eMount the board onto a standard TS32 or TS35 DIN rail, ensuring secure mechanical seating.\u003c\/li\u003e\n\u003cli\u003eUse keyed Weidmuller connectors as specified to ensure reliable power transmission and prevent connection errors.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance for airflow around the module to avoid heat buildup, especially given the density of the 8-channel output.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring conforms to local electrical safety standards (e.g., IEC or VDE) before energizing the system.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to protect the sensitive electronic components on the board.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the function of the FC-PDB-0824P?\u003c\/h3\u003e\u003cp\u003eIt acts as a power distribution hub for 24Vdc systems, allowing a single input source to be safely branched into eight fused output channels for field devices.\u003c\/p\u003e\u003ch3\u003eCan I replace the fuses on this board?\u003c\/h3\u003e\u003cp\u003eYes, each of the eight channels is protected by a 5x20mm 2A slow-acting fuse, which can be replaced during maintenance if a fault occurs on a specific channel.\u003c\/p\u003e\u003ch3\u003eIs this module suitable for hazardous locations?\u003c\/h3\u003e\u003cp\u003eThe unit features conformal coating for environmental protection and is designed for use in industrial control cabinets; always verify site-specific safety requirements against the module's datasheet before installation in hazardous areas.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48832276758718,"sku":"FC-PDB-0824P","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_9e85fad7-5c19-4693-83f7-8c1171113923.jpg?v=1788376004","url":"https:\/\/www.autooiltech.com\/ar\/products\/honeywell-fc-pdb-0824p-power-distribution-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}