{"product_id":"honeywell-900rta-l001-analog-input-rtp","title":"Honeywell 900RTA-L001 Analog Input RTP","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Honeywell \u003cstrong\u003e900RTA‑L001 \u003c\/strong\u003eis an Analog Input Remote Terminal Panel (RTP) used with Honeywell C300\/Series 8 I\/O. It provides conditioned termination for analog field loops, ensuring stable, isolated, and reliable signal interfacing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: 900RTA‑L001\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Analog Input Remote Terminal Panel (RTP)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Experion C300 \/ Series 8 I\/O\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e: 4–20 mA analog transmitter loops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eChannel Support\u003c\/strong\u003e: Multi‑channel analog input termination\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Field‑to‑system isolation via RTP architecture\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e: Screw‑terminal field wiring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e: Supports stable analog loop termination and noise reduction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Works with C300 controller diagnostics for loop integrity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 °C to +55 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Process transmitters, analog measurement loops, field signal interfacing\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStable Analog Termination\u003c\/strong\u003e: Provides reliable termination for 4–20 mA field loops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNoise‑Resistant Design\u003c\/strong\u003e: Reduces electrical interference for accurate measurement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: Fully compatible with Honeywell C300\/Series 8 architecture\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Durability\u003c\/strong\u003e: Built for continuous operation in harsh environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEasy Maintenance\u003c\/strong\u003e: Accessible terminals simplify loop checks and replacement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eConsistent Performance\u003c\/strong\u003e: Maintains stable analog measurement across operating conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWhat_is_the_900RTA‑L001\u003c\/strong\u003e It is an analog input RTP for Honeywell Experion C300\/Series 8 systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWhat_signals_does_it_support\u003c\/strong\u003e It supports standard 4–20 mA analog transmitter loops.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eIs_it_compatible_with_C300\u003c\/strong\u003e Yes, it is designed specifically for C300\/Series 8 I\/O.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDoes_it_provide_isolation\u003c\/strong\u003e Isolation is achieved through RTP architecture and wiring separation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHow_is_it_installed\u003c\/strong\u003e It mounts on the RTP panel and connects via screw‑terminal wiring.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48188930556094,"sku":"900RTA-L001","price":620.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/900RTA-L001_1.png?v=1784791041","url":"https:\/\/www.autooiltech.com\/ar\/products\/honeywell-900rta-l001-analog-input-rtp","provider":"AutoOilTech Limited","version":"1.0","type":"link"}