{"product_id":"honeywell-51305887-150-analog-input","title":"Honeywell 51305887-150 Analog Input","description":"\u003cp\u003eConfigured for analog-to-digital signal conversion in distributed control network architectures, the \u003cstrong\u003eHoneywell 51305887-150\u003c\/strong\u003e (\u003cstrong\u003e51305887\u003c\/strong\u003e Analog Input Module) provides direct electrical execution of field variable ingestion and Ethernet transmission.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51305887-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.16 x 12.70 x 2.54 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10 to 95 percent RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e1000 samples\/sec per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, HART protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V input-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, CSA, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Integration and Isolation Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module executes digital transmission of sensor data via the 4-20 mA HART loop protocol overlay, bridging remote transmitter parameters to the central logic controller.\u003c\/li\u003e\n\u003cli\u003ePhysical galvanic separation is implemented to maintain a 500 V input-to-output isolation threshold, preventing ground loop propagation across the distributed control system backplane.\u003c\/li\u003e\n\u003cli\u003eRedundant input configuration support dictates fail-over state execution, allowing continuous process monitoring without interrupting ongoing Ethernet polling cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the backplane communication standard utilized by the 51305887-150 hardware?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on the standard Ethernet protocol to transmit the digitized 12-bit analog data to the main CPU processors.\u003c\/p\u003e\n\u003cp\u003eQ: Can this hardware component operate in a fault-tolerant configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 51305887-150 supports redundant input architectures, permitting dual-module pairing to sustain continuous data polling during a single-path hardware failure.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit process signal electrical transients?\u003c\/p\u003e\n\u003cp\u003eA: It integrates 500 V input-to-output isolation hardware boundaries, shielding the logic circuits and the primary power bus from field-side electrical surges.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the chassis securely to the designated panel footprint, ensuring structural stability to limit low-frequency mechanical vibration.\u003c\/li\u003e\n\u003cli\u003eTerminate field wiring using the torque specifications dictated by the termination block manual. Shielded twisted-pair cables must be grounded at a single point to suppress electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eAdhere strictly to the defined operating envelope of -20 to 60 deg C ambient. Ensure standard spatial clearance between adjacent rack components to permit passive convective thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC power supply voltage output at the physical terminals prior to inserting the analog module into the receiving slot to avoid over-voltage logic\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48599644078270,"sku":"51305887-150","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-08-07_16-10-06.png?v=1786090390","url":"https:\/\/www.autooiltech.com\/ar\/products\/honeywell-51305887-150-analog-input","provider":"AutoOilTech Limited","version":"1.0","type":"link"}