{"product_id":"honeywell-51304163-300-tdc-3000-pm-communication-module","title":"Honeywell 51304163-300 TDC 3000 \/ PM Communication Module","description":"\u003cp\u003eConfigured for specific technical task in Universal Control Network (UCN) platforms, the \u003cstrong\u003eHoneywell 51304163-300\u003c\/strong\u003e (\u003cstrong\u003e51304163-300\u003c\/strong\u003e Modem Board) provides direct physical\/electrical execution. The board-level industrial hardware component acts as an active transceiver interface to execute real-time serialization, signal level translation, and high-velocity process data routing across centralized Honeywell distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304163-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lb (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 80 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal operating voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eModem Board \/ UCN Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Lineage\u003c\/td\u003e\n\u003ctd\u003eProcess Manager (PM) \/ TDC 3000 Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eUniversal Control Network (UCN), Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-485, Optional Ethernet link expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Data Velocity\u003c\/td\u003e\n\u003ctd\u003eUp to 1 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003eComponent of PM control section (1 of 5 dependent modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Rails\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol and Base Interface Interfacing\u003c\/strong\u003e The communication module manages data serialization alongside dense field instrumentation banks operating via the 4-20 mA HART loop protocol. While field multiplexers handle low-level analog current telemetry, this module executes high-level data packaging, routing secondary digital parameters into the wider distributed control system (DCS) computing infrastructure without affecting raw process variable tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation and Noise Resistance\u003c\/strong\u003e The transceiver architecture implements onboard physical galvanic separation structures across the serial lines and network ports. This boundary path blocks electrical transients, localized induction spikes, and grounding differentials from crossing from the field networks into the internal Process Manager backplane bus, preventing frame corruption and data dropouts during active loop control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle signal routing across mixed RS-232 and RS-485 physical links?\u003c\/p\u003e\n\u003cp\u003eA: The internal logic circuits decouple the transceivers natively at the hardware tier. When handling multi-drop RS-485 arrays or point-to-point RS-232 linkages, the onboard processors arbitrate frame priority and execution timing, converting serial telemetry packets directly into the standardized high-speed data formats required by the main system bus.\u003c\/p\u003e\n\u003cp\u003eQ: What initialization behavior occurs if the auxiliary 24 VDC supply encounters a temporary dropout?\u003c\/p\u003e\n\u003cp\u003eA: A power dip below nominal limits triggers an immediate hardware-level reset routine. The module drops off the active network bus to prevent emitting malformed frames, entering a passive safe state until the power conditioning circuits verify a stable 24 VDC rail, after which it re-establishes network node tracking.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47651829383358,"sku":"51304163-300","price":750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-16_10-52-30_8a52d327-7729-4826-9758-6bf0184be77f.png?v=1781582191","url":"https:\/\/www.autooiltech.com\/ar\/products\/honeywell-51304163-300-tdc-3000-pm-communication-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}