{"product_id":"general-electric-ds200tccbg3ane-mark-v-series","title":"General Electric DS200TCCBG3ANE Mark V Series","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS200TCCBG3ANE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TCCB\u003c\/strong\u003e Common Extended Analog I\/O Board, serves as a dedicated hardware component for signal scaling and conditioning within Speedtronic Mark V power generation control systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCCBG3ANE identification code provides the following hardware specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDS200\u003c\/strong\u003e: Standard Mark V Series assembly type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTCCB\u003c\/strong\u003e: Functional product abbreviation (Common Extended Analog I\/O Board).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG3\u003c\/strong\u003e: Group Three Mark V Series product grouping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANE\u003c\/strong\u003e: Revision history (Artwork and functional revision grades).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200TCCBG3ANE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 mm x 178 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplane derived (5 VDC \/ 24 VDC rails)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3PL connector (to STCA board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-1 mA, RTD, Generator\/Bus Voltage, Line Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Integration and DCS Interface\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Pathing\u003c\/strong\u003e: The board performs signal conditioning (filtering, amplification, and isolation) on incoming 4-20 mA loops, ensuring that field sensor data remains within the input range required by the STCA processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Protection\u003c\/strong\u003e: Signal integrity is maintained via onboard isolation circuits that decouple high-voltage generator\/bus inputs from the low-voltage control logic, preventing common-mode noise from affecting the measurement chain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation (CJC) Stability\u003c\/strong\u003e: The board facilitates precise scaling for RTD and analog inputs, supporting the accurate thermodynamic calculations required for turbine temperature monitoring and power system synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the function of Jumper J14 on the DS200TCCBG3ANE?\u003c\/p\u003e\n\u003cp\u003eA: Jumper J14 is utilized to bridge the RS232 serial communication port to the DCOM (Distributed Component Object Model) interface, enabling network-based data transfer between software components within the Mark V control environment.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific jumpers for generator monitoring?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Jumpers J1 through J5 are configured to enable generator\/bus voltage monitoring and line current monitoring functions specifically required for Mark V LM system operations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Board Interface\u003c\/strong\u003e: The module must be properly interfaced with the R5 core terminal board and the TCEB board in the P1 core. Ensure that all ribbon cables are seated firmly in the 3PL connectors to maintain secure data transmission to the STCA board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Port Usage\u003c\/strong\u003e: Jumpers J15 and J16 are reserved exclusively for maintenance diagnostic routines. These should not be configured during standard operation; ensure they are set according to the factory-default state unless active troubleshooting is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Shielding\u003c\/strong\u003e: Given the board's operational range of -30 to +65 deg C, ensure that the cabinet-level cooling maintains consistent thermal profiles. Avoid routing high-power AC cables in close proximity to the analog input terminal blocks to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48170756374718,"sku":"DS200TCCBG3ANE","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-14_10-50-34_2f42e416-3246-4597-9aee-9f355d392669.png?v=1784281381","url":"https:\/\/www.autooiltech.com\/ar\/products\/general-electric-ds200tccbg3ane-mark-v-series","provider":"AutoOilTech Limited","version":"1.0","type":"link"}