{"product_id":"ge-ur81h-communications-module","title":"GE UR81H Communications Module","description":"\u003cp\u003eConfigured for network interfacing in Universal Relay (UR) platforms, the \u003cstrong\u003eGE Multilin UR81H\u003c\/strong\u003e (\u003cstrong\u003eUR81H\u003c\/strong\u003e Communications Module) provides direct physical and electrical execution of high-speed Ethernet and serial data exchange across SCADA and DCS architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR81H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eUR chassis modular form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRelay backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet (10\/100 Mbps), RS485\/Serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The UR81H interfaces with the internal UR backplane to facilitate low-latency data polling. This velocity is necessary for ensuring that protection event records, metering data, and control commands are propagated to the network with minimal delay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e The module enables native support for IEC 61850, Modbus, and DNP3 protocols. Its internal logic is structured to handle deterministic packet scheduling, ensuring that supervisory traffic does not interfere with the relay's internal protection timing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e By providing redundant communication channels, the UR81H allows for the expansion of network connectivity without consuming additional rack space for standard I\/O slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e The hardware platform supports field-upgradeable firmware, allowing for the addition of new protocol stacks and updated cybersecurity patches to maintain NERC CIP compliance throughout the product lifecycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the UR81H provide fault tolerance through redundant channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the UR81H is engineered with redundant communication channel support. In the event of a primary port or network link failure, the module is capable of transitioning to the standby channel, ensuring that communication with the SCADA\/DCS remains active.\u003c\/p\u003e\n\u003cp\u003eQ: Is the UR81H module compatible with all generations of the GE Multilin UR relay chassis?\u003c\/p\u003e\n\u003cp\u003eA: The UR81H is designed for integration across the Universal Relay platform. Compatibility should be verified against the specific chassis backplane revision to ensure full support for high-speed Ethernet and legacy serial interfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the UR81H into the designated communication slot of the UR chassis. Ensure the locking mechanisms are fully secured to maintain contact pressure on the backplane connector, which is mandatory for signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the UR relay chassis to the substation earth bus via a low-impedance ground connection. This prevents the buildup of potential differences between the module chassis and external network cabling shields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize shielded, category-rated Ethernet cabling and high-quality serial interconnects. Route communication lines through dedicated signal conduits to avoid inductive noise ingress from high-voltage primary circuits, which can cause packet errors or interface re-initialization.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47981312082110,"sku":"UR81H","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-07_17-32-15_69e48925-2853-42b2-b7a1-232f9e373796.png?v=1783419095","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-ur81h-communications-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}